Page | 25
The
C3-510
only requires one command string to recall a preset.
However a login command is required to access the unit and a logout
is advised to close the connection.
Unlike C2 products C3 commands can be put in the same string,
however a [
\x0d
] (CR) is required to separate the commands. There
are three individual elements to the command string -
To log in – [
login(admin,adminpw)
]
To load preset #1 – [
preset.take=1
]
To log out – [
logout
]
1.
Load preset #1
login(admin,adminpw)
\x0d
preset.take=1
\x0d
lo
gout
\x0d\x0a
Button Labels
A sheet of self-adhesive button labels are included. These can be
applied to the buttons to identify each function. Blank labels are
provided for the user to create custom labels. A simple way to do this
is using ‘black on clear’ label tape applied to the blank labels.
Please note: The layout and design of the sheet of button labels may
vary depending on the regional variation.
A removable protective film covers the labels, remove this before use.
Additional sheets of printed and blank labels can be purchased by
contacting your tvONE Sales representative.