background image

44

 

6.7 Spare 

parts 

Please quote the equipment serial number with every order for components! 

Panel-shape models 

Models 

PMD2PLUS/PZ 

Rev.1.000 

HIPEPLUS/PZ 

Rev.2000 

SMD600PLUS/PZ 

Rev.1.002 

02PN20/PZ  

Rev.1.001  

PMD3PLUS/PZ 

Rev.1.000 

Description 

Code 

Code 

Code 

Code 

Code 

Plastic case control unit  with connecting cables  

64824 

64083 

61013 

64962 

67561 

Metal case control unit  with connecting cables  

64286 

64084 

61016 

64963 

67562 

Front cover with lock of Plastic case control unit   

24873 

24873 

24873 

24873 

24873 

Installation kit for Plastic case control unit   

49961 

49961 

49961 

49961 

49961 

Installation kit for Metal case control unit   

49962 

49962 

49962 

49962 

49962 

Keys of the keypad (4) 

29415 

29415 

29415 

29415 

29415 

RX antenna (adapted for photocells installation) * 

54379 

66334 

63494 

51787   

51769 

TX antenna  (adapted for photocells installation) * 

54380 

66333 

63493 

54428   

51771 

Electronic cards of the antenna dual colour archway LED bar 

45401 

63496 

63496 

45401 

45401 

720mm cross-bar with holes 

55639 

55639 

55639 

55639 

55639 

720mm cross-bar without holes 

55640 

55640 

55640 

55640 

55640 

760mm cross-bar with holes 

55652 

55652 

55652 

760mm cross-bar without holes 

55653 

55653 

55653 

820mm cross-bar with holes 

55641 

55641 

55641 

820mm cross-bar without holes 

55642 

55642 

55642 

Upper cable protection cap  of the panel with knobs 

45663 

45663 

45663 

45663 

45663 

Upper cable protection cap  of the panel with screws 

55154 

55154 

55154 

55154 

55154 

Round photocells module 

32716 

32716 

Standard 2 beam oval photocells module  

46113 

High precision 4 beam oval photocells module  

46112 

46112 

46112 

Protection caps for Lower connection module 

55155 

55155 

55155 

55155 

55155 

Protection caps for 720mm crossbars and control unit 

55644 

55644 

55644 

55644 

55644 

Protection caps for 760mm crossbars and control unit 

55654 

55654 

55654 

Protection caps for 820mm crossbars and control unit 

55645 

55645 

55645 

Lower connection module 

55637 

55637 

55637 

Emergency battery option: Lower connection module with  Pb 0.8Ah battery  

APSM2plus/P APSM2plus/P APSM2plus/P APSM2plus/P APSM2plus/P 

 

Pb 

12V-0,8Ah 

battery

19

19

19

19

19

Emergency battery and Ethernet option – Lower connection module with Pb 0.8Ah batteries 

APSIM2plus/P 
APSIM3plus/P 

APSIM2plus/P 
APSIM3plus/P 

APSIM2plus/P APSIM3plus/P APSIM3plus/P 

Long Life Crossbar Battery Back-Up option   

55681 

55681 

55681 

55681 

55681 

Battery compartment with batteries 

49510 

49510 

49510 

49510 

49510 

Pb 12V - 9Ah battery  

36891 

36891 

36891 

36891 

36891 

100-240V~ , 100W IP67 Power supply adaptor 

48092 

48092 

48092 

48092 

48092 

100-240V~ , 80W Power supply adaptor 

44041 

44041 

44041 

44041 

44041 

Cable for Power supply adaptor, CEE plug 

1559 

1559 

1559 

1559 

1559 

Cable for Power supply adaptor,  UL plug 

1574 

1574 

1574 

1574 

1574 

Cable for Power supply adaptor,  UL L5-15P twist lock plug 

49040 

49040 

49040 

49040 

49040 

Cable for Power supply adaptor,  UK plug 

1570 

1570 

1570 

1570 

1570 

Column-shape models 

Models 

PMD2PLUS/EZ Rev.1.004 

02PN20/EZ Rev.1.001 

PMD3PLUS/EZ Rev.1.000 

Description 

Code 

Code 

Code 

Plastic case control unit  with connecting cables  

64888 

64966 

67552 

Metal case control unit  with connecting cables  

64889 

64967 

67553 

Front cover with lock of Plastic case control unit   

24873 

24873 

24873 

Installation kit for Plastic case control unit   

45315 

45317 

45317 

Installation kit for Metal case control unit   

45316 

45318 

45318 

Keys of the keypad (4) 

29415 

29415 

29415 

RX antenna (adapted for photocells installation) * 

54358 

52859   

52165 

TX antenna  (adapted for round photocells installation) * 

54359 

52961   

52166 

Electronic cards of the antenna dual colour archway LED bar 

45401 

45401 

45401 

720mm cross-bar with holes 

45156 

45156 

45156 

820mm cross-bar with holes 

45226 

Cross-bar locking unit (1 piece) 

24878 

24878 

24878 

Upper cable protection cap  of the panel with knobs 

45417 

45417 

45417 

Upper cable protection cap  of the panel with screws 

55668 

55668 

55668 

Round photocells module 

46982 

High precision 4 beam oval photocells module 

56109 

56109 

Installation kit for Plastic case control unit  and photocells 

45317 

45317 

45317 

Installation kit for Metal case control unit  and photocells 

45318 

45318 

45318 

Protection caps for 720mm crossbars and control unit 

54113 

54113 

54113 

Protection caps for 820mm crossbars and control unit 

55667 

Ethernet option 

APSIM2plus/E

APSIM3plus/E

APSIM3plus/E

100-240V~ , 100W IP67 Power supply adaptor 

48092 

48092 

48092 

100-240V~ , 80W Power supply adaptor 

44041 

44041 

44041 

Cable for Power supply adaptor, CEE plug 

1559 

1559 

1559 

Cable for Power supply adaptor,  UL plug 

1574 

1574 

1574 

Cable for Power supply adaptor,  UL L5-15P twist lock plug 

49040 

49040 

49040 

Cable for Power supply adaptor,  UK plug 

1570 

1570 

1570 

* specify the options to include with the order. Example: TX antenna with photocells: 

 

code of the TX Antenna

 

code of the Lower connection module (panel shape only)

 

code of the Kit of photocells 

 

code of the Electronic cards of the antenna archway LED bar (2 pieces). 

303-670-1099

Summary of Contents for 02PN20

Page 1: ...lutions each model offers the best cost performance ratio for its specific application Options Some functions parts indicated as options in this manual are included as default in high level models Ell...

Page 2: ...S TO THE LOCAL PROGRAMMING PHASE USING THE PASSWORD 31 4 3 2 FREE ACCESS TO LOCAL PROGRAMMING PHASE WITHOUT PASSWORD 31 4 3 3 COMMAND EXECUTION IN LOCAL PROGRAMMING 32 4 3 4 EXIT FROM LOCAL PROGRAMMIN...

Page 3: ...n of the earth ground safety terminal will render the device dangerous Intentional cutting or disconnection is strictly forbidden Whenever there is any suggestion that the level of protection has been...

Page 4: ...ially dangerous substances Do not short circuit the contacts serious risk of burning and breakage Do not dispose of battery in fire danger of explosion Any maintenance or repair involving the device b...

Page 5: ...c casing or metal casing is designed to be attached directly to the crossbar of the archway An embedded Infra Red interface allows the use of an accessory remote control unit which acts as the control...

Page 6: ...na Rf Reflectors for transit counting options on column version C1 crossbar fitted with holes for mounting the control unit C2 crossbar without holes panel shape version K ON OFF special key Indicator...

Page 7: ...et LAN interface Web server for set up and remote data log Real Time clock with battery backup Non volatile Memory for Metal Detector events storage wireless Wi Fi interface APSIM3Plus version only su...

Page 8: ...is intended for upgrading the standard version to outdoor applications according to IEC 60950 22 This kit includes shelters crossbar protection covers for power supply and waterproof power supply ada...

Page 9: ...mperature 20 C to 70 C on demand 37 C to 70 C Storage temperature 37 C to 70 C Relative humidity 0 to 95 without condensation Standard Version UW 115 4 5 UW 50 2 630 00 24 3 4 6 5 1 4 UW 2255 88 8 205...

Page 10: ...30 24 8 6 5 1 4 2050 80 7 UW 115 4 5 UW 50 2 UW 170 6 7 UW 660 00 26 340 13 4 UW 155 6 1 2035 80 1 2275 89 6 401 15 8 440 17 3 990 39 560 22 UW 362 14 3 Dimensions UW 720mm OPTION 760mm or 820mm panel...

Page 11: ...ration This configuration can be applied in outdoor sheltered permanent installations or outdoor non sheltered short term installations single event entrance 3 1 1 Examples of possible sources of inte...

Page 12: ...ced in direct contact with the MD 6 Sources of vibration Unstable Floor The MD gate shall be anchored to a stable floor Avoid installing on wood or metal platforms unless necessary In this latter case...

Page 13: ...y the Security Authority Components needed Unpacking Scissors and Pliers Phillips screwdriver n 1 Kit C E I A FGA TFV Metal free clothes Clean Tester Tracksuit Gym shoes No metal personal effects meta...

Page 14: ...RX parts Configuration A Configuration B Configuration A Configuration B XRU XRU XRU XRU Configuration A Configuration B Configuration A Configuration B Typical application fitted with two Metal Detec...

Page 15: ...mp protection cover of the lower connection module ccp protection cover of CU control unit and C1 crossbar cp protection cover of C2 crossbar Pictures of main components Positioning the panels Tilt do...

Page 16: ...t of the panel taking care that the logo is facing the floor Attach the C2 crossbar with no holes to the upper part of the panel making sure that the logo is facing up RX C1 C2 Configuration B with TX...

Page 17: ...en key AW2 or TX1 to free them Configuration A Lift the archway placing it on the supports S1 and S2 Attach the control unit to the lower crossbar using vc screws and AW2 Allen key included in the ins...

Page 18: ...g panel connector Lock the cable connectors using the short screwdriver cK included into the installation kit Insert the cables into the crossbar groove Fix the cables in position using the clips on t...

Page 19: ...C2 Each cap s secured by a short cord to a cable clip Remount covers cp Attach the protection cover ccp of the crossbar C1 using the hooks h and the knobs vp taking care to push it towards the panel c...

Page 20: ...river photocell vc control unit mounting screw PC Protection covers ccp protection cover of CU control unit and C1 crossbar Pictures of main components Positioning the columns Place F spacers on the f...

Page 21: ...les for the control unit close to the TX column Insert the crossbar guide pins into the holes on the inside of the column Configuration A TX RX Configuration B with TX column on the right when facing...

Page 22: ...guration B Connecting the control unit Connect the cables coming from the control unit as illustrated in the figure below Connect each cable to the column connector winding the cable in excess if nece...

Page 23: ...PH2 AW Photocells Reflectors Phillips screwdriver and Allen wrench included in the installation kit Remove the pc cap using AW key pc Open the Ph photocell module using a PH2 cross head screwdriver Pa...

Page 24: ...ability and acting as an adapter allow the archway to be easily relocated In order to prevent the archway from tipping over in case of bumps the stable anchoring to the ground is anyway mandatory Meta...

Page 25: ...ribed in the previous step but passing the output cable of the AC DC adapter through one of the strain reliefs present on the protection cover Connect the input cable of the AC DC adapter to the mains...

Page 26: ...ext step use the UP and DOWN keys to change a numeric value or an answer Y yes to N no and vice versa In the following any operator s action is indicated between and OTS function can be executed also...

Page 27: ...TX mains ALARM VOLUME SELECT ENTER AV ENTER Selection of the Alarm Volume MINIMUM VOLUME SELECT ENTER MV ENTER Selection of the Minimum Volume lower limit for alarm volume adjustment ALARM TONE SELEC...

Page 28: ...onto the X ray unit belt Subject the floor to normal and above normal stress walk heavily change direction In case of strong gusts of air or wind EVA function can be useful to compensate archway vibra...

Page 29: ...d to be compatible For safety reasons anchoring the unit to the floor is mandatory Anchoring methods shall be agreed prior to proceeding with the following steps Marble or tiled floors or Carpeted flo...

Page 30: ...o bumps or mechanical exertion 3 7 Personalisation 3 7 1 Settings check If required by the specifications of the Security Authority change the programming setting to refine the operating mode Enter pr...

Page 31: ...will be terminated automatically if no commands are entered for a period of 2 minutes 4 3 Local programming Use the keypad on the inside panel of the control unit The PROG key is used to enter and ex...

Page 32: ...ower supply and serial communication cables together in order to avoid loops ATTENTION in order to avoid any damage to the PC s interface make sure that the cable does not include a connection to pin...

Page 33: ...TER P _10000 number of passages through the antenna TA_ 2350 the total number of passages with alarm TR_23 5 the alarms passages ratio as a percentage MA_ 1500 number of passages with alarm due to a m...

Page 34: ...92 168 0 101 IP I192 168 0 101 IS International Security Standard 1 30 C R Selects a security level corresponding to an international standard During normal operation the current Security Level is dis...

Page 35: ...stance will be required from C E I A personnel OFV Functionality check at operator level C Activates the OFV test For details of the procedure see the instructions included in the OFV kit OTS One Touc...

Page 36: ...ach command is changed by entering the opposite value to the current one to the right of the character If the user does not wish to change the command state he she can simply press ENTER and the curso...

Page 37: ...ction module power indicator entry pacing lights entry side GREEN transit allowed RED busy transit not allowed zone alarm indication exit side in case of alarm a group of LEDs lights up to pinpoint th...

Page 38: ...l be performed according to local Security Authority procedures taking into account that The indication given through light bars that illuminate where the presence of an object is detected is solely m...

Page 39: ...ming phase starts the last used command will appear Press the arrow keys to select the AV Alarm Volume or AT Alarm Tone function if a different one is displayed Press the ENTER key to change the AV se...

Page 40: ...eiver antenna A in the form of an archway made up of a transmitter part TX a receiver part RX a power supply adapter PSA FG PCU TX RX A CU PSA R RX PSA TX CU RX PSA TX CU Block diagram of a metal dete...

Page 41: ...e calibration Test piece specified by the Security Standard in use 12 months mandatory Battery replacement Supplied Allen Key N 5 2 batteries Recommended 3 years maximum 5 years 6 2 Diagnosis Generic...

Page 42: ...ing a chip card try at first to perform again the operation completely and correctly If the self diagnosis message appears again carry out the recommended action listed in the following table Display...

Page 43: ...out FGA step Increase LC parameter setting Excessive sensitivity at ground level f i detection of shoes Excessive sensitivity at ground level Start OTS procedure and carry out FGA step Decrease LC pa...

Page 44: ...rtment with batteries 49510 49510 49510 49510 49510 Pb 12V 9Ah battery 36891 36891 36891 36891 36891 100 240V 100W IP67 Power supply adaptor 48092 48092 48092 48092 48092 100 240V 80W Power supply ada...