background image

COD

0330002

MULTI GAS 4 IN 1 DEVICE IP67

EN IEC 60079-0:2018, EN IEC 60079-11:2012

1

Distruburote Ufficiale

 · UFO ITALIA S.r.l. • P.zza IV Novembre 4 • 20124 Milano (MI) Italia

+39 02.87176653  [email protected]  P.IVA/C.F. 11031750968

RILEVATORE DI GAS 4 in 1

4 in 1 GAS DETECTOR

4 in 1 GASMELDER

Distruburote Ufficiale

UFO ITALIA S.r.l. 

• P.zza IV Novembre 4 • 20124 Milano (MI) Italia

+39 02.87176653 

 [email protected] 

 P.IVA/C.F. 11031750968

Summary of Contents for Proline 0330002

Page 1: ...ALIA S r l P zza IV Novembre 4 20124 Milano MI Italia 39 02 87176653 info ufo safety com P IVA C F 11031750968 RILEVATORE DI GAS 4 in 1 4 in 1 GAS DETECTOR 4 in 1 GASMELDER Distruburote Ufficiale UFO...

Page 2: ...EN IEC 60079 11 2012 2 Distruburote Ufficiale UFO ITALIA S r l P zza IV Novembre 4 20124 Milano MI Italia 39 02 87176653 info ufo safety com P IVA C F 11031750968 Manuale in Italiano pag 3 English Use...

Page 3: ...terfaccia del display 5 4 2 Accensione 6 4 3 Funzionamento 6 4 4 Utilizzo e settaggio delle funzioni 7 4 4 1 Gas zero 7 4 4 2 Calibrazione dei gas 8 4 4 3 Impostazione dei parametri 9 4 4 4 Dati salva...

Page 4: ...antenendo i lavoratori al sicuro e prevenendo danni gravi alle strutture Il rilevatore adottando un sensore di eccellente qualit effettua la rilevazione in modo di diffusione naturale Ha una buona sen...

Page 5: ...l sistema in tempo reale Avviso LED audio e vibrazione per perdite di gas Applicazioni Cantieri nei settori petrolifero chimico della protezione ambientale della metallurgia e di altri settori Ambient...

Page 6: ...e mostrato nella Figura 4 entra nello stato di rilevamento In questo momento viene visualizzata la concentrazione di O2 H2S CO e gas combustibile nell ambiente L indicatore di stato lampeggia una volt...

Page 7: ...estro per selezionare il tipo di gas quindi premere il pulsante centrale per accedere al sottomenu Gas Zero N No ot ta a p pr re en nd de en nd do o c co om me e e es se em mp pi io o i il l m mo on n...

Page 8: ...successivo effettuare la calibrazione al gas selezionato come mostrato nella Figura 15 Come mostrato nella Figura 15 fare clic con il tasto destro per selezionare il punto di calibrazione i valori de...

Page 9: ...rica Premere il pulsante centrale per entrare nel canale per visualizzare l unit come mostrato in Figura 21 Ripristinare le impostazioni predefinite Ripristina tutte le configurazione del modulo senso...

Page 10: ...pulsante destro per selezionare la pagina di registrazione degli allarmi e con il pulsante centrale clicca per tornare Nell interfaccia di visualizzazione dei record di lettura possibile visualizzare...

Page 11: ...ia principale 4 4 7 Spegnere il dispositivo Selezionare e premere il pulsante centrale per spegnere il dispositivo fare clic con il tasto destro per annullare lo spegnimento e tornare all interfaccia...

Page 12: ...e l altra estremit alla presa del rilevatore di gas il rilevatore di gas si accender e visualizzer automaticamente lo stato di carica 4 6 1 Ricarica Quando il rilevatore in carica la barra di avanzam...

Page 13: ...ti 7 2 Il rilevatore potrebbe non funzionare correttamente con gas interferenziale ad alta concentrazione 7 3 Per evitare risultati errati o possibili danni al rilevatore utilizzare e maneggiare il ri...

Page 14: ...ntattare il produttore o il rivenditore per sostituire il sensore del gas Non calibrato per molto tempo Si prega di calibrarlo in tempo Indicazione errata dell orario La tensione della batteria esauri...

Page 15: ...Distruburote Ufficiale UFO ITALIA S r l P zza IV Novembre 4 20124 Milano MI Italia 39 02 87176653 info ufo safety com P IVA C F 11031750968 APPENDIX I N No ot ta a p pe er r a al lt tr ri i g ga as s...

Page 16: ...cted and level of accuracy 18 3 2 Features 18 4 Operation function 18 4 1 Display interface function description 18 4 2 Turn on 19 4 3 Operation 19 4 4 Use and set functions 20 4 4 1 Gas zero 20 4 4 2...

Page 17: ...inuously and simultaneously It is widely used in the area where explosion proof is required or toxic gas leaks like underground channels or mining industry so as to protect the workers life and avoid...

Page 18: ...0 60s Indication LCD displays real time and system status LED audo and vibration alert for gas leakage Application Worksites in petroleum chemical envisonmental protection metallurgy and other industr...

Page 19: ...o display the detector is in the normal detecting status 4 3 Operation In the main detecting interface Figure 1 press the left button to enter the self check state as shown in Figure 5 Self check incl...

Page 20: ...ot th he er r g ga as s s se et tt ti in ng g m me et th ho od ds s a ar re e s si im mi il la ar r a an nd d w wi il ll l n no ot t b be e r re ep pe ea at te ed d h he er re e Make gas zero calibra...

Page 21: ...he next menu make the calibration to the selected gas as shown in Figure 15 As shown in Figure 15 right click to select the calibration point the calibration point values are arranged in ascending ord...

Page 22: ...Press the middle button to enter the relative channel to view the unit as shown in Figure 21 Restore factory settings Restore all configuration information of the sensor module as before shipment N N...

Page 23: ...d left click right click to select the alarm record page and middle click to return On the read record viewing interface you can view the alarm value alarm status and alarm time of the relative gas ch...

Page 24: ...e if the backlight is not on press any key to turn on it In the main detecting interface and backlight is on press the left button to make sound light and vibration self check In the alarm state press...

Page 25: ...e in a safe area in time otherwise the detector will shut down automatically as shown in Figure 37 W Wa ar rn ni in ng g T Th he e d de et te ec ct to or r c ca an nn no ot t d de et te ec ct t g ga a...

Page 26: ...he detector please operate and handle the detector in accordance with the manual 7 4 The detector should be not stored or used neither under the circumstance with caustic gas such as C12 nor under the...

Page 27: ...ion Sensor is overdue Please contact the manufacturer or dealer to replace the gas sensor Uncalibrated for long time Please calibrate it in time Fault indication of time Battery voltage is used up Ple...

Page 28: ...Ufficiale UFO ITALIA S r l P zza IV Novembre 4 20124 Milano MI Italia 39 02 87176653 info ufo safety com P IVA C F 11031750968 APPENDIX I N No ot te e F Fo or r o ot th he er r g ga as se es s a an nd...

Page 29: ...eschreibung der Display Schnittstelle 31 4 2 Einschalten 32 4 3 Operation 32 4 4 Funktionen verwenden und einstellen 33 4 4 1 Zero Gas 33 4 4 2 Gas Kalibrierung 34 4 4 3 Einstellung der Parameter 35 4...

Page 30: ...ird h ufig in Bereichen eingesetzt in denen Explosionsschutz erforderlich ist oder giftige Gase austreten wie z B in unterirdischen Kan len oder im Bergbau um das Leben der Arbeiter zu sch tzen und Sc...

Page 31: ...0s Anzeige LCD Anzeige f r Echtzeit und Systemstatus LED Ton und Vibrationsalarm bei Gasaustritt Anmeldung Baustellen in der Erd l Chemie Umweltschutz Metallurgie und anderen Industrien Arbeitsumfeld...

Page 32: ...em Gas in der Umgebung an Die Statusanzeige blinkt einmal alle 9 Sekunden um anzuzeigen dass sich der Detektor im normalen Erfassungsstatus befindet 4 3 Operation Dr cken Sie in der Haupterkennungssch...

Page 33: ...en H Hi in nw we ei is s A Am m B Be ei is sp pi ie el l v vo on n K Ko oh hl le en nm mo on no ox xi id d w we er rd de en n a an nd de er re e G Ga as se ei in ns st te el ll lu un ng gs sv ve er rf...

Page 34: ...ie Kalibrierung mit dem ausgew hlten Gas durch wie in Abbildung 15 dargestellt Wie in Abbildung 15 dargestellt klicken Sie mit der rechten Maustaste um den Kalibrierungspunkt auszuw hlen die Werte der...

Page 35: ...en Kanal aufzurufen und die Einheit anzuzeigen wie in Abbildung 21 dargestellt Ripristinare le impostazioni predefinite Ripristina tutte le configurazione del modulo sensore come prima della spedizion...

Page 36: ...en Maustaste klicken Sie mit der rechten Maustaste um die Alarmdatensatzseite auszuw hlen und klicken Sie mit der mittleren Maustaste um zur ckzukehren Auf der Anzeigeoberfl che f r Leseaufzeichnungen...

Page 37: ...palte ist das Datum der Kalibrierung wie in Abbildung 32 gezeigt 4 4 6 Zur ck W hlen Sie und dr cken Sie die mittlere Taste um das Men zu verlassen und zur Hauptschnittstelle zur ckzukehren 4 4 7 Auss...

Page 38: ...ng g d de es s G Gr re en nz zw we er rt ts s Die Statusanzeige wird rot und zeigt OL an der Melder gibt einen schnellen Piepton von sich und die rote Alarmleuchte blinkt schnell und vibriert gleichz...

Page 39: ...als 85 betr gt In Innenr umen und die Luft darf keine sch dlichen Gase oder Verunreinigungen enthalten die eine korrosive Wirkung auf den Detektor haben 6 Paketinhalt Anzugkoffer Verpackung 1 St cK Ga...

Page 40: ...f llig Wenden Sie sich bitte an den Hersteller oder H ndler um den Gassensor auszutauschen Unkalibriert f r lange Zeit Bitte kalibrieren Sie es rechtzeitig St rungsanzei ge der Zeit Batteriespannung i...

Page 41: ...ITALIA S r l P zza IV Novembre 4 20124 Milano MI Italia 39 02 87176653 info ufo safety com P IVA C F 11031750968 APPENDIX I H Hi in nw we ei is s F F r r a an nd de er re e G Ga as se e u un nd d B Be...

Page 42: ...Distruburote Ufficiale UFO ITALIA S r l P zza IV Novembre 4 20124 Milano MI Italia 39 02 87176653 info ufo safety com P IVA C F 11031750968 www ufo safety com RIVENDITORE RE SELLER...

Reviews: