OPERATOR'S INTERVENTION
PROBLEMS
CAUSES
SOLUTIONS
THE CONTROL BOARD DOES NOT
SWITCH-ON
No electric power supply.
• Check the battery disconnector is active
• Check the battery charge and main fuse
state.
Fault in control board
• Contact the authorised assistance.
THE STARTER MOTOR DOES NOT TURN
No electric power supply to starter motor.
• Check the battery charge, the main fuse
and starter motor electric wiring state.
Emergency button pressed and
EMERGENCY led lights on.
• Release the emergency button.
THE MACHINE DOES NOT PRE-HEAT
SPARK PLUGS UPON START-UP
Probable spark plugs pre-heat relay fault.
• The the spark plugs pre-heat relay operation
and replace it if required.
THE STARTER MOTOR TURNS BUT THE
DIESEL ENGINE DOES NOT START
No fuel.
• Fill the tank with fuel and try again.
Fuel is not reaching the engine.
• Check diesel oil solenoid valve control relay
operation.
• Pump fuel using the manual pump.
• Check the manual pump is not broken.
THE DIESEL ENGINE WORKS IN AN
IRREGULAR MANNER AND TENDS TO
SWITCH-OFF
Clogged diesel oil filters.
• Replace the diesel oil filters.
Faulty manual pump.
• Replace the manual pump.
Diesel oil tank in reserve.
• Add diesel oil.
Clogged air filters.
• Clean or replace the air filters.
BATTERY CHARGER ALARM ON
Alternator is not charging the battery.
• Check the alternator's transmission belt and
replace it if required.
• Check alternator and diode bridge
WATER TEMPERATURE ALARM ON AND
DIESEL ENGINE SWITCHES OFF
Insufficient cooling liquid level and/or dirty
engine cooling radiator.
• Top-up the cooling liquid level and clean the
radiator.
Faulty water pump
• Replace water pump
PUMPING STOPS
Unsuitable mix and pumping pressure at limit • Make mix suitable for pumping.
Open hopper grid
• Check the grid is properly closed and the
hopper is blocked.
High hydraulic oil temperature.
• Top-up the hydraulic oil tank.
• Check the hydraulic oil level and clean the
hydraulic oil radiator. Wait for the oil to cool
with diesel engine on.
One of the pumping control solenoid valves is
faulty.
• If the solenoid valve does not work in
manual mode, the cause is the solenoid valve
• Check the solenoid valve is powered (red
LED on cap must switch-on)
Faulty pumping sensors.
• If the machine does not work in manual
mode, a sensor is faulty; the faulty sensor's
LED does not normally switch-on.
THE MIXER DOES NOT TURN
Function not active on the control board.
• Activate function from control board.
Open hopper grid.
• Close the hopper grid.
Foreign body present blocking the mixer.
Check pressure on the pumping manometer.
• Stop engine and remove the foreign body.
Mixer control solenoid valve faulty. Check the
relative LED switches on.
• Check the mixer's solenoid valve wiring and
relative relay.
WORSENING OF MACHINE
PERFORMANCES
Disc and/or wear plate worn.
Register the S valve.
Worn pumping pistons.
• Replace the pumping pistons.
Mix to be pumped excessively dense and
cannot be pumped.
• Modify mix making it more liquid.
Summary of Contents for Beton Master
Page 1: ...Serial number Year OPERATION AND MAINTENANCE MANUAL BETON MASTER IS19 07 561270 EN ORIGINAL ...
Page 2: ......
Page 5: ...11 2 WARRANTY 57 ...
Page 6: ......
Page 8: ...1 CE DECLARATION 8 58 561270 IS19 07 EN ...
Page 14: ...3 TECHNICAL DESCRIPTION 14 58 561270 IS19 07 EN ...
Page 18: ...4 TRANSPORTATION AND HANDLING 18 58 561270 IS19 07 EN ...
Page 24: ...5 INSTALLATION 24 58 561270 IS19 07 EN ...
Page 28: ...6 SAFETY 28 58 561270 IS19 07 EN ...
Page 52: ...9 SCRAPPING 52 58 561270 IS19 07 EN ...
Page 55: ...TROUBLESHOOTING 10 561270 IS19 07 EN 55 58 ...
Page 56: ...10 TROUBLESHOOTING 56 58 561270 IS19 07 EN ...
Page 58: ...11 RESPONSIBILITY OF THE OPERATOR 58 58 561270 IS19 07 EN ...