![Turbosol Beton Master Operation And Maintenance Manual Download Page 46](http://html1.mh-extra.com/html/turbosol/beton-master/beton-master_operation-and-maintenance-manual_1181315046.webp)
8
MAINTENANCE
46/58
561270 - IS19/07 - EN
FIG.63
- Reinstall the delivery flange and the grease fitting.
- Reinstall the upper hopper and the safety grid.
- Start the machine and make sure the S-valve switches regularly.
8.5
CHANGING THE FIRST OIL FILTER
The following steps must be carried out with the machine switched off and the oil cooled down.
The hydraulic oil tank is provided with two filters. Replace the filter on the cover every 500 hours and the filter inside the tank
every 1000 hours.
- To change the filter (FIG. 64-REF. 1) unscrew the four screws on the oil filter inspection cover on the fixed casing.
- Unscrew the filter cap (FIG. 64-REF. 2) and remove and replace the filter cartridge.
- Screw the cap back on (FIG. 64-REF. 2) and fasten the inspection cover with the screws.
3
1
2
FIG.64
8.6
CHANGING THE SECOND OIL FILTER
- Take down the fixed casing by removing the screws on the casing mounts and on the brackets that fasten it to the hydraulic
oil tank (FIG. 65).
Summary of Contents for Beton Master
Page 1: ...Serial number Year OPERATION AND MAINTENANCE MANUAL BETON MASTER IS19 07 561270 EN ORIGINAL ...
Page 2: ......
Page 5: ...11 2 WARRANTY 57 ...
Page 6: ......
Page 8: ...1 CE DECLARATION 8 58 561270 IS19 07 EN ...
Page 14: ...3 TECHNICAL DESCRIPTION 14 58 561270 IS19 07 EN ...
Page 18: ...4 TRANSPORTATION AND HANDLING 18 58 561270 IS19 07 EN ...
Page 24: ...5 INSTALLATION 24 58 561270 IS19 07 EN ...
Page 28: ...6 SAFETY 28 58 561270 IS19 07 EN ...
Page 52: ...9 SCRAPPING 52 58 561270 IS19 07 EN ...
Page 55: ...TROUBLESHOOTING 10 561270 IS19 07 EN 55 58 ...
Page 56: ...10 TROUBLESHOOTING 56 58 561270 IS19 07 EN ...
Page 58: ...11 RESPONSIBILITY OF THE OPERATOR 58 58 561270 IS19 07 EN ...