![Turbosol Beton Master Operation And Maintenance Manual Download Page 33](http://html1.mh-extra.com/html/turbosol/beton-master/beton-master_operation-and-maintenance-manual_1181315033.webp)
USE AND OPERATION
7
561270 - IS19/07 - EN
33/58
FIG.
REF.
DESCRIPTION
27
1
Ignition key
27
2
Activation button
27
3
Hour meter
27
4
Pumping and sucking start/stop
27
5
Mixer Start/stop/Reverse
27
6
Vibrating screen activation/stop
27
7
Local/remote control selector switch
27
8
High pressure washer
27
18
S-valve manual control and pumping cylinders
27
19
S-valve manual control and pumping cylinders
28
1
Emergency stop button
28
2
Flow rate regulator
28
3
Accelerator
28
4
Auxiliary circuit manometer
28
5
Pumping circuit manometer
28
6
High pressure water pump manometer (opt.)
INDICATORS (on)
FIG.
REF.
DESCRIPTION
27
9
Activation
27
10
Spark-plugs pre-heat
27
11
Alternator failure
27
12
Fuel tank reserve
27
13
High hydraulic oil temperature
27
14
High motor cooling liquid temperature
27
15
Air filter clogging
27
16
Low motor oil pressure
27
17
Safety devices intervention
TAB.08
Indications on the control panel alarms are provided below:
- Battery re-charge alarm (FIG.35-REF.11)
It is possible to continue working with the machine for a maximum of 200 minutes (approx. 4 hours) to allow completing the
work in progress, after this alarm is signalled. After this time it is no longer possible to work as the engine automatically turns
off after it is started. Avoid the battery discharging by intervening to restore charge correct operation.
(Request the authorised after-sales assistance intervention).
- Diesel oil level alarm (FIG.35-REF.12)
This alarm is signalled when the tank level drops below minimum. We recommend topping-up.
It is possible to work, but with the risk of completely finishing the diesel oil, making it difficult to re-start the motor even after fuel
top-up.
- Hydraulic oil temperature alarm (FIG.35-REF.13)
This alarm automatically switches pumping off.
The machine remains on to allow the oil to cool down.
- Engine cooling liquid temperature alarm (FIG.35-REF.14)
This alarm automatically switches the motor off.
- Air filter alarm (FIG.35-REF.15)
This alarm only appears on the console. Clean or replace filters.
- Motor oil pressure alarm (FIG.35-REF.16)
Should a fault be found upon starting the motor (i.e. broken motor wiring or disconnected pressure switch) the warning light
flashes and start-up is inhibited. Upon restoring normal conditions the warning light goes out and the motor may be started.
This alarm automatically switches the motor off. Restore the oil level and search for leaks.
- Safety devices activation alarm (FIG.35-REF.17)
This alarm indicates the activation of the machine safety devices.
This alarm automatically switches pumping off.
Summary of Contents for Beton Master
Page 1: ...Serial number Year OPERATION AND MAINTENANCE MANUAL BETON MASTER IS19 07 561270 EN ORIGINAL ...
Page 2: ......
Page 5: ...11 2 WARRANTY 57 ...
Page 6: ......
Page 8: ...1 CE DECLARATION 8 58 561270 IS19 07 EN ...
Page 14: ...3 TECHNICAL DESCRIPTION 14 58 561270 IS19 07 EN ...
Page 18: ...4 TRANSPORTATION AND HANDLING 18 58 561270 IS19 07 EN ...
Page 24: ...5 INSTALLATION 24 58 561270 IS19 07 EN ...
Page 28: ...6 SAFETY 28 58 561270 IS19 07 EN ...
Page 52: ...9 SCRAPPING 52 58 561270 IS19 07 EN ...
Page 55: ...TROUBLESHOOTING 10 561270 IS19 07 EN 55 58 ...
Page 56: ...10 TROUBLESHOOTING 56 58 561270 IS19 07 EN ...
Page 58: ...11 RESPONSIBILITY OF THE OPERATOR 58 58 561270 IS19 07 EN ...