Controller Configuration
30
Entering the Service Mode
To access the ‘Service Mode’, whilst in the Pre-
Heat or Oven Ready screens, press the Time
and Right function key simultaneously for 3
seconds, Menu 1 will display.
Service Parameters
Service parameters are identified by a number,
shown on the left hand side of the display screen.
Use the ‘Select Up - Down’ keys to scroll to the
Service Mode Menu Number required.
Press the ‘Select’ key to enter the Recipe Menu
required.
Press 'Exit', 'Right' Function key to return to the
Menu Screen / Exit the Controller Configuration
Menu’s.
MENU 1
1.
Set Temp Offset
Sometimes it is necessary to make a small
adjustment to the real temperature.
To carry out this function, place a digital
thermometer into the centre of the oven and
allow the oven temperature to stabilise.
The temperature display on the oven will
show the real temperature measured by the
temperature sensor without offset.
Press the ‘Select’ key to enter Item 1 ‘Set
Temp Offset’. The Offset Temp screen will
display.
Use the ‘Select Up - Down’ keys to enter
the actual difference that the digital
thermometer shows.
Press 'Save', 'Left' Function key to save the
settings and return to Menu 1.
Offset Temp Default – 005°C.
Press the ‘Select - Down’ key to scroll to
the Item 2 - ‘Calibrate the Probes’.
Offset