Turbines Incorporated 

Cryogenic Flow Delivery System 

CDS1000 Manual (Rev E)

 

 

 

CDS1000 Page 

ii

 

Notice 

 

Proprietary Notice 

The information contained in this publication is derived in part from proprietary data and trade 
secrets.  This information has been prepared for the expressed purpose of assisting operating and 
maintenance personnel in the efficient use of the instrument described herein.  Publication of this 
information does not convey any rights to use or reproduce it or to use for any purpose other than 
in connection with the installation, operation, and maintenance of the equipment described 
herein. 
Copyright 2014 
Printed in the USA.  All Rights Reserved. 
 
 
 

SAFETY INSTRUCTIONS 

The following instructions must be observed. 

 

Every effort has been made to design and manufacture this instrument to be safe for its 
intended use.  A hazardous situation may occur if this instrument is not used for its intended 
purpose or is used incorrectly.  Please note operating instructions provided in this manual. 

 

The instrument must be installed, operated, and maintained by personnel who have been 
properly trained.  Personnel must read and understand this manual prior to installation and/or 
operation of the instrument. 

 

The manufacturer assumes no liability for damage caused by incorrect use of the instrument 
or for modifications or changes made to the instrument. 

 

Technical Improvements 

Turbines Incorporated

 may modify the technical data herein without notice. 

 

Summary of Contents for CDS1000

Page 1: ...Box 933 15935 US Hwy 283 N Altus OK 73522 0933 Seneca 864 882 4544 http turbinesincorporated com Manual part number 900484 Revision E Copyright 2013 2016 Turbines Inc All rights reserved Information c...

Page 2: ...inted in the USA All Rights Reserved SAFETY INSTRUCTIONS The following instructions must be observed Every effort has been made to design and manufacture this instrument to be safe for its intended us...

Page 3: ...tallation 7 Operation 8 Programming 9 Specifications 13 Hardware 13 Software 13 Troubleshooting 14 Illustrations 15 Wiring 17 Return Policy 18 All Returns 18 Warranty Claim 18 Non Warranty Repair 18 E...

Page 4: ...ally exclude damage that has resulted from improper installation of improper maintenance of unauthorized change or modification to improper operation of and or misuse or abuse of the subject equipment...

Page 5: ...DS1000 The displayed total is corrected for temperature by sensing the resistance of the RTD temperature probe Delivery information consisting of 17 selectable parameters is transmitted via Bluetooth...

Page 6: ...s the normal display for this mode The Detail screen is also accessible in this mode without a password Programming Mode The Programming mode and associated menu s permit the CDS1000 to be configured...

Page 7: ...b Use at least 4 20 bolts with lock washers and or lock nuts 4 Install cables and connect to the rear panel Do not over tighten Connectors should be hand tight a Route cables and tie wrap excess so th...

Page 8: ...ss to PRINT only if printer is enabled To View uncompensated total Press to RESET totalizer to ZERO flow must be stopped Press to see unit DETAILS list and perform Battery Test Indicates Pump Cooldown...

Page 9: ...must be removed 1 Calibration 1 Average K factor 2 Linearizer Table 3 Linearizer Press 0 OFF 1 ON 2 Configuration 1 LOX 2 LIN 3 LAR 4 LCO2 5 LN2O 6 CCO2 7 MAPP 8 LPG Type value press ENT Not normally...

Page 10: ...Type value press ENT max 9999 Default 1234 for Turbines Bluetooth Printer Next Page Next Page 2 Totalize during alarm 3 Pump cooldown timer 4 Pump cooldown delay 5 Pump ON during alarm 6 Count while...

Page 11: ...rs 4 Print Example 005 19 Apr 11 14 29 Lin table 004 19 Apr 11 10 51 Factor 158 3444 003 16 Apr 11 15 54 Lin table 002 15 Apr 11 11 54 Factor 149 853 001 12 Mar 11 13 11 Lin table Press any key to con...

Page 12: ...port on the rear of the unit labeled OUTPUT The print timeout controls when the ticket totals are adjusted for a new ticket When the timer expires the value for start is set to the last value for stop...

Page 13: ...control self regulating non sweating temperature activated heater Power External 9 26 Vdc self resetting fuse 0 6A with heater OFF 1 6A with heater ON Transient protection Internal Rechargeable NiMH...

Page 14: ...from turbine meter Reconnect signal cable to coil b With a screw driver rapidly scratch coil below the threads on the bottom surface c Observe CDS1000 counts or signal light slightly illuminates or f...

Page 15: ...Turbines Incorporated Cryogenic Flow Delivery System CDS1000 Manual Rev E CDS1000 Page 15 Illustrations...

Page 16: ...Turbines Incorporated Cryogenic Flow Delivery System CDS1000 Manual Rev E CDS1000 Page 16...

Page 17: ...n Color Function Color 1 Pressure Input 4 20mA Brown Brown 1 Pump NC Brown 1 RTS N C 2 Pressure Input 4 20mA White White 2 Pump C White 2 CTS N C 3 Internal GND Blue Blue 3 Pump NO Blue 3 RX Red 4 Rat...

Page 18: ...anty Repair If a Product is returned for repair Turbines R D LLC will provide an estimate of the repair charges on a time and materials basis and the time required to make the repair If any repair est...

Page 19: ...rompted depress Enter and then ESC this places the CDS1000 in the prove mode operating screen The Prove mode allows repeated access to adjust the Kfactor while the cooldown timer flow inhibit of the r...

Page 20: ...e and remove the PEM With the CDS1000 powered up normally depress Setup and if not already in Prove mode enter your password Select Avg Kfactor by depressing 1 Example A new Kfactor is calculated to b...

Page 21: ...t page Power Off 11 12 2012 B Delete duplicate programming on Pg11 12 21 2012 C Incorporate Pressure PCO control feature and menu items 06 11 2014 D Added missing menu item 3 2 7 Pump off flow rate er...