Tunze Multicontroller 7093 Instructions For Use Manual Download Page 5

5

x7093_8888

Fig. 1

(Fig. 1) Scope of delivery

-

multicontroller 7093 base unit

-

holding Velcro fastener (2 pieces)

7

708.05

photo-electric cell

8/10 7092.30

cable connector (2 pieces)

Fig. 2

(Fig. 2) Accessories available

14

7092.30

cable connector for additional Turbelle

 ®

15

7092.34

branch adapter for two Turbelle

 ®

 electronic

16

7090.10

remote control button with a 2 m cable for Foodtimer

-

7090.24

adapter cable for Turbelle

 ®

 7200/7400

Instructions for Use

Multicontroller 7093
General aspects

Multicontroller 7093 is an electronic control device for Turbelle

 ®

electronic pumps 7210 (P), 7310 (P), 7410 (P), and their variants.
Elder versions of Turbelle

  ®

 electronic (7200, 7400) can be

connected to the multicontroller by means of adapter cable 7092.24.
Each of the four ports can be connected up to one Turbelle

  ®

electronic by means of cable connector 7092.30 or to two Turbelle

®

 electronic by means of branch adapter 7092.34, thus producing

a maximum number of eight pumps to be controlled.

Installation

For installation select a dry place protected against splash water
and moisture (please do not mount above the aquarium). Please
observe the cable length of the cable connector to your pump drivers
as they must not be extended. In addition, please ensure that the
photo-electric cell has to be placed in the illumination area of your
aquarium lighting (cf. day-and-night change-over function).
The device can be attached to a smooth surface (e.g. plastic
surface) by means of the self-adhesive Velcro tape attached.
Remove the release paper from the tape and press it against the
housing with the adhesive surface against the smooth surface.

Connection and preparation of the initial operation

Prior to any dis/connection of the cable connectors to your Turbelle

®

 electronic, always remove the power supply unit of the pumps

from the mains socket outlet or de-energise.
Use the 5-pole cable connector enclosed to connect the
multicontroller to the driver of Turbelle

  ®

 electronic. For driver

7240.22 of the Turbelle

 ®

 electronic sets (7200 / 7400), please use

adapter 7090.24 instead of the cable connector.
If a coding plug is connected to the driver of your pump, remove
this plug first. If you are using a driver which does not need a
coding plug for the operation without the multicontroller,
please set the “Power” button on your driver to 100 % and the
“Pulse” button to off. Otherwise the functions of the driver
and the multicontroller superimpose each other, which may
cause the standstill of the pump (superimposition of two
power settings). The resulting wear damage will cause an
exclusion of guarantee.

Subsequently connect the power supply unit of the pumps up to
the mains socket outlet. The multicontroller is now ready for pulsed
operation, which will be indicated by the lit foodtimer LED (2). In
addition, the two LEDs on the buttons 4a/6a or 4b/6b (cf. Fig. 1),
respectively, will be flashing in the cycle of the pulse time set. The
yellow LEDs on ports (8) to (11) indicate whether a control
signal is released at the port or whether the pump is running,
respectively.

Functions

Pulsed operation or wave simulation (Figs. 1 and 3)

The pulsed operation produces biologically active flow pulses
(waves). For each channel two different performance adjustments
can be set on buttons 4a / 4b and 6a / 6b, which change over in the
cycle of the pulse time set on button (1). The pulse time can be set
from approx. 1 to 3 seconds.
For the pulsed operation, slide (13) has to be brought into the
middle position.
 Pumps can be connected to ports (8) and (9) for
channel 1. Ports (10) and (11) have been provided for channel 2.
Note: The pulsed operation will work only, if at least one pump is
connected to port (8) or (10). Pumps connected to one channel
have the same pulse heights and depths corresponding to the
adjustment on buttons 4a / 4b and 6a / 6b. If a pulsed operation is
not desired on one or both channels during the day, turn the pulse
controller on button (1) to off position whilst the LED is lit between
4b and 6b. The pumps will then operate without pulse during the
day. This is the only way to ensure that the pump will be operated
with the requested performance after a longer power failure.

Pulsed operation in the same direction or in the
opposite direction

For channel 1 and channel 2 the power of the pulsed flow can be
adjusted in the same direction by controllers 4a = 6a and 4b = 6b
or in the opposite direction by controllers 4a = 6b and 4b = 6a or
according to own ideas (cf. Fig. 3).

Summary of Contents for Multicontroller 7093

Page 1: ...1 x7093_8888 multicontroller 7093 Gebrauchsanleitung Instructions for Use Mode d emploi ...

Page 2: ...er Sollten Sie einen Treiber verwenden der für den Betrieb ohne multicontroller keinen Codierstecker benötigt dann stellen Sie den Power Knopf auf IhremTrei ber auf 100 und den Pulse Knopf auf off Ansonsten überlagern sich die Funktionen des Treibers und des multicontrollers Das kann zum regelmäßigen Stillstand der Pumpe führen Überlagerung zweier Leistungseinstellungen Die daraus resultierenden V...

Page 3: ...rfolgt mit An schluß der beiliegenden Photozelle an Buchse 7 Halten Sie die Photozelle zunächst probeweise so in den Strahlungsbereich der Aquarienleuchte Abstand ca 30cm daß die angeschlossene Pumpe zu pulsen anfängt Danach können Sie das Schutzpapier vom Selbstkleber auf der Rückseite der Photozelle abziehen und die Zelle dauerhaft an erprobter Stelle befestigen Achtung Die Photozelle niemals in...

Page 4: ...ehör ist für die An schlußbuchse 9 die Ferntaste Art Nr 7090 10 erhältlich Was ist Wenn die LED 2 beim Anschluß der Netzteile nicht gleich leuch tet und die Pumpen nicht arbeiten 6 98 Der Foodtimer ist gerade aktiv Warten Sie 5 10 Minuten bis dieser abgelaufen ist Die Anlage startet automatisch Die Verbindungskabel sind an den falschen Buchsen ange schlossen Die Verbindungskabel vom Treiber zum mu...

Page 5: ...he driver of your pump remove this plug first If you are using a driver which does not need a coding plug for the operation without the multicontroller please set the Power button on your driver to 100 and the Pulse button to off Otherwise the functions of the driver and the multicontroller superimpose each other which may cause the standstill of the pump superimposition of two power settings The ...

Page 6: ...ly to the tested position Warning Never attach the photo electric cell in the direct vicinity of a mercury discharge lamp or a high pressure mercury vapour lamp Keep a minimum distance of 30 cm 11 8 in 20 cm 7 87 in in case of high voltage fluorescent lamps as otherwise a light and heat damage will be unavoidable Automatic interval operation or low and high tide Fig 4 If two or more Turbelle elect...

Page 7: ... it is impossible to forget to switch the system on after feeding A remote control button article No 7090 10 is available as an accessory to be connected to port 9 6 98 What has happened if the LED 2 does not light up when the power supply units are connected and the pumps do not work The foodtimer is active at the moment Wait for 5 to 10 minutes until the foodtimer time has run down The system wi...

Page 8: ...uni d une fiche de codage il faut la retirer avant le raccordement Si vous utilisez un driver fonctionnant sans fiche de codage lors de l utilisation sans multicontroller il faut mettre le bouton Power de votre driver sur 100 et le bouton Pulse sur off Sinon les fonctions du driver et ceux du multicontroller peuvent interférer et provoquer systématiquement l arrêt de la pompe superposition de deux...

Page 9: ...tubes fluorescents sinon des dégâts de chaleur et de lumière sont inévitables Fonctionnement à intervalles automatiques ou simulation des marées fig 4 En utilisant deux ou plusieurs Turbelle electronic la simulation des marées devient possible par arrêt et remise en route alternés des pompes branchées aux prises 8 et 10 et celles branchées aux prises 9 et 11 Le temps de commutation des intervalles...

Page 10: ... Remèdes au cas où la DEL 2 ne s allume pas immédiatement et les pompes ne se mettent pas en route après le branchement des blocs d alimentation sur le secteur Le foodtimer est activé Attendez 5 10 minutes jusqu à ce que la pause nourriture soit écoulée L installation redémarre automatiquement Les câbles de raccordement ne sont pas branchés sur les bonnes prises Les câbles de raccordement entre le...

Reviews: