19
ENG
and the reset button has been pressed in order to ensure that the sau-
na is ready for use. If the door is open or if the reset button has not
been pressed, the sauna will not be heated.
Install the door switch outside the sauna room at the top edge of the
door at least 300 mm from the door’s inner corner. Install the switch
in the doorframe and the magnet in the door. The distance between
the switch and the magnet must not exceed 18 mm. The reset button
should be installed outside the sauna room in a suitable place.
GND
Door
Magnetic switch
GND
Reset
Reset button
ON/OFF SWITCH
J14 GND
J14 on/off
On/Off button
Startup takes place when the electrical circuit is completed. When the
gap is closed, the sauna will be switched on with the previous sauna
session’s temperature setting. When the circuit is broken, the sauna
heater is switched off.
More detailed installation and operating instructions are supplied with
the product itself and are also available at website
www.tulikivi.fi.
CUT-OFF CLOCK
Tulikivi sauna heaters have a built-in cut-off clock that restricts the
heating time as follows:
1. Apartment block shared saunas: can be switched on and off with-
out restriction over a 12-hour period. If the heater has been in
continuous use for 12 hours, it will revert to standby status and
will be operable again after a 6-hour break. (DIP switches set at
100)
2. Hotel saunas: the default 24-hour setting for the sauna heater is
4 hours on, 6 hours off, 8 hours on and 6 hours off. (DIP switches
set at 010)
3. For home use, the maximum time the sauna heater can be on is
set at 6 hours. (DIP switches set at 001)
4. In supervised commercial use, there is no cut-off clock. (DIP
switches set at 000)
The operation of the cut-off clock is determined using the DIP switch-
es on the relay card. FOR HOME USE, THE CUT-OFF MUST ALWAYS BE
USED AND THE DIP SWITCH SETTING MUST NOT BE CHANGED.
THERMOCOUPLE INSTALLATION
1. Connect the thermocouple to the sau-
na heater control card.
(NEG) red
(POS) yellow
2. Pass the thermocouple through the
hole near the top edge of the connection box.
3. First fill the stone compartment with sauna stones up to the height
of the thermocouple.
4. Push the end of the thermocouple right to the end of the installa-
tion pipe.
5. Position the installation pipe in the stone compartment. Attach the
pipe by slotting it in place in the hole in the stone compartment
wall.
Note: the pipe must not touch the heating elements.
6. Place the rest of the sauna stones in the stone compartment.
NOTE! THERMOCOUPLE CABLE SHOULD EXTENT ONLY THE COM-
PENSATION CABLE.
OTHER CONNECTIONS: DOOR SWITCH AND RESET BUTTON
(OPTIONAL ACCESSORY)
In order to use the heater’s remote startup function, the door switch
and reset button must be installed. When the heater is set to switch on
with the weekly timer, the system checks that the sauna door is closed
yellow
(12 Vdc)