LOCAL
Returns the instrument to local operation and unlocks the keyboard. Will
not function if LLO is in force.
LRN <character data>
Install data for a previous
∗
LRN? command.
MODE <cpd>
Set the mode to <CONT>, <GATE>, <TRIG>, <SWEEP> or TONE.
OUTPUT <cpd>
Set the main output <ON>, <OFF>, <NORMAL> or <INVERT>.
PHASE <nrf>
Set the slave generator phase to <nrf> degrees.
POSNMKRCLR <cpd>
Clear all position markers from arbitrary waveform <cpd>.
POSNMKRPAT
<cpd1>,<nrf1>,<nrf2>,<cpd2>
Put the pattern <cpd2> into the arbitrary waveform <cpd1> from start
address <nrf1> to stop address <nrf2>.
POSNMKRRES <cpd>,<nrf>
Clear the position marker at address <nrf> in arbitrary waveform <cpd>
to 0 (low).
POSNMKRSET <cpd>,<nrf>
Set the position marker at address <nrf> in arbitrary waveform <cpd> to
1 (high).
PULSDLY <nrf>
Set the pulse delay to <nrf> sec.
PULSPER <nrf>
Set the pulse period to <nrf> sec.
PULSWID <nrf>
Set the pulse width to <nrf> sec.
PULTRNBASE <nrf>
Set the pulse-train base line to <nrf> Volts.
PULTRNDLY <nrf1>,<nrf2>
Set the delay of pulse-train pulse number <nrf1> to <nrf2> sec.
PULTRNLEN <nrf>
Set the number of pulses in the pulse-train to <nrf>.
PULTRNLEV <nrf1>,<nrf2>
Set the level of pulse-train pulse number <nrf1> to <nrf2> Volts.
PULTRNMAKE
Makes the pulse-train and runs it - similar to the WAVE PULSTRN
command.
PULTRNPER <nrf>
Set the pulse-train period to <nrf> sec.
PULTRNWID <nrf1>,<nrf2>
Set the width of pulse-train pulse number <nrf1> to <nrf2> sec.
QER?
Query and clear query error number register.
REFCLK <cpd>
Set the ref. clock bnc to <IN>, <OUT>, <MASTER> or <SLAVE>.
SEQCNT <nrf1>,<nrf2>
Set count for sequence segment <nrf1> to <nrf2>.
SEQSEG <nrf>,<cpd>
Set the status of sequence segment <nrf> to <ON> or <OFF>.
SEQSTEP <nrf>,<cpd>
Set the 'step on' parameter for sequence segment <nrf> to <COUNT>,
<TRGEDGE> or <TRGLEV>.
SEQWFM <nrf>,<cpd>
Set the 'waveform' parameter for sequence segment <nrf> to <cpd>.
SWPCENTFRQ <nrf>
Set the sweep centre frequency to <nrf> Hz.
SWPDIRN <cpd>
Set the sweep direction to <UP> or <DOWN>.
SWPMANUAL <cpd>
Set the sweep manual parameters to <UP>, <DOWN>, <FAST>,
<SLOW>, <WRAPON> or <WRAPOFF>.
SWPMKR <nrf>
Set the sweep marker to <nrf> Hz.
SWPSPACING <cpd>
Set the sweep spacing to <LIN> or <LOG>.
SWPSPAN <nrf>
Set the sweep frequency span to <nrf> Hz.
SWPSTARTFRQ <nrf>
Set the sweep start frequency to <nrf> Hz.
SWPSTOPFRQ <nrf>
Set the sweep stop frequency to <nrf> Hz.
81