OPERATING MANUAL
DC VOLTAGE MEASUREMENT
1. Connect common test lead to the COM terminal, then insert the red test lead to V Ω
terminal.
2. Set the function selector to
V
and connect the test lead in parallel with the power or
load to be measured.
3. The meter will auto-range to display the most appropriate measurement.
NOTE:
•
Do not input voltage higher than 1000V as damage to the meter may result.
•
When measuring at mV range, relative mode must be used.
•
After completing all measurement operations, disconnect the test leads from the
measured circuit.
•
When the measured voltage is higher than the safety voltage 30V DC, the meter displays
high voltage the warning prompt ”
“
•
When measured voltage is higher than 1000V DC, the meter beeps and displays the high
voltage warning prompt.