E459EN_05.DOC
Tool
assembly
15
Mounting and aligning the machine in the
workstation
1. Rotate the machine carrier into the correct position.
2. Fasten the machine in the workstation with the help of the
screw (110) (wrench can be found among the accessories).
3. Loosen the two clamping levers (46).
4. The plate (45) in which the machine is held can be adjusted
only by turning the star grips (49).
5. This will cause the pressure die to be repositioned in relation to
the strips (41) and (42). (Pressure die = hardened support
piece on which the sheet edge to be machined is slid along
during the work process).
6. Set chamfer size and sheet thickness at the two knurled nuts
(31) and (34) on the machine.
ca. 0-0.5 mm
41
29
42
29 Pressure
die
41 Strips
42 Strips
Setting value of the machine pressure die in relation to
the strips at the workstation
7. Pressure die min. 0, max. 0.5 mm above the support area of
the strips (41) (42).
Fig. 13403