E479EN_07.DOC
Maintenance
17
1
2
3
1
Gear head
2
Tapping gear housing and
tapping support plate
3 Ventilation
slit
Maintenance positions on the TKA 300-0
Maintenance point
Procedure and interval
Empfohlene Schmiermittel
Recommended
lubricants
Gearbox and
gear head (1)
After 100 operating hours, arrange
for a trained engineer
to relubricate or to replace the
lubricating grease.
"G1" lubricating grease
0139440
Integral tapping gear
housing and integral
tapping support plate (2)
Clean and grease if necessary
"G3" lubricating grease
0353969
Ventilation slit (3)
Clean as required.
-
-
Multi-edge cutter
Turn or insert a new one if
necessary.
- -
Impeller
Change if necessary.
-
-
Maintenance positions and maintenance intervals
Fig. 30823
Tab. 6