15
Device fuse: 10 A (slow-acting) (T 10 A)
T 10 A
Fig. 5
Fuse 230 V (Combi E)
The fuse and the power supply lines must only be replaced by
an expert!
The unit must be disconnected from the mains (all
poles) before opening the electronic housing lid.
The fuse is in the power electronics (14) beneath the elec-
tronic housing lid.
This fine fuse must always be replaced with a fuse of the
same type: 10 A, slow-acting, interrupting capacity “H”.
T 10 A
14
Fig. 6
Overheating protection 230 V (Combi E)
The 230 V heating facility has a mechanical overheating
switch. If the 12 V power supply is interrupted during opera-
tion or during the after-run period, for example, the tempera-
tures within the unit could activate the overheating protection.
Fig. 7
To reset the overheating protection, allow heater to cool,
remove connection cover and press red reset button.
Technical data
Determined in accordance with EN 624 or under Truma test
conditions
Device category
I
3 B/P
in accordance with EN 437
Type of gas
Liquid gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Water contents
10 litres
Heating time from approx. 15 °C to approx. 60 °C
Boiler approx. 20 minutes (measured according to EN 15033)
boiler approx. 80 min.
Pump pressure
max. 2.8 bar
System pressure
max. 4.5 bar
Rated thermal output
(automatic operating levels)
Gas mode
Combi 2 E*: 2000 W
Combi 4 (E)*: 2000 W / 4000 W
Combi 6 (E)*: 2000 W / 4000 W / 6000 W
Electrical mode
Combi 2 E* / Combi 4 E* / Combi 6 E*: 900 W / 1800 W
Mixed mode (gas and electrical)
Combi 2 E* /
Combi 4 E*: max. 3800 W
Combi 6 E*: max. 5800 W
Gas consumption
Combi 2 E*: 160 g/h
Combi 4 (E)*: 160 - 320 g/hr.
Combi 6 (E)*: 160 - 480 g/hr.
Standby heat requirement (all units)
Gas mode 5.2 g/hr.
Destination country
(see type plate)
Combi 2 E*: Only approved for GB and IR
Air delivery volume
(free-blowing without warm air duct)
Combi 2 E* /
Combi 4 (E)*: With 3 warm air outlets max. 249 m³/h
With 4 warm air outlets max. 287 m³/h
Combi 6 (E)*: With 4 warm air outlets max. 287 m³/h
Power consumption at 12 V
boiler
Combi 2 E* /
Combi 4 (E)*: Max. 5.6 A for short periods
(average power consumption approx. 1.1 A)
Combi 6 (E)*: Max. 5.6 A for short periods
(average power consumption approx. 1.3 A)
Boiler heating maximum 0.4 A
Stand-by approx. 0.001 A
Heating element – FrostControl (optional): maximum 0.4 A
Power consumption at 230 V
3.9 A (900 W) or 7.8 A (1800 W)
Weight
(not containing water)
Heater unit:
15.1 kg
Heater unit with peripheral devices: 15.6 kg
* (UK) CP plus ready
Right reserved to make technical changes!
Dimensions
450 mm
510 mm
300 mm
Fig. 8