Always observe the operating instructions and “Impor-
tant operating notes” prior to starting! The digital / ana-
logue control panels are described in separate operating 
instructions. 

The vehicle owner is responsible for correct 

operation of the appliance.

The installer or vehicle owner must apply the yellow sticker 
with the warning information, which is enclosed with the ap-
pliance, to a place in the vehicle where it is clearly visible to 
all users (e.g. on the wardrobe door)! Ask Truma to send you 
stickers, if necessary.

Before using for the first time, it is essential to flush the 
entire water supply system through with clean water. If 

the heater is not being used, always drain the water contents 
if there is a risk of frost! 

There shall be no claims under 

guarantee for damage caused by frost!

Room thermostat

To measure the room temperature, an external room tempera-
ture sensor (2) is located in the vehicle. The position of the 
sensor is determined by the vehicle manufacturer depending 
on the vehicle model. More information can be found in the 
operating instructions for your vehicle.

2

Fig. 2

The thermostat setting at the control panel depends on the 
personal heating requirement and the design of the vehicle, 
and must be individually determined. 

Safety/drain valve

A. FrostControl 

(Safety/drain valve with integral frost protection / 
optional in UK version)

FrostControl is a currentless safety/drain valve. When there 
is a danger of frost, it automatically drains the contents of 
the boiler through a drainage socket. If excessive pressure is 
present in the system, pressure will be automatically intermit-
tently equalized through the pressure relief valve.

a

b

c

d

Fig. 3

a  = Rotary switch position “On” 
b = Push button position “Closed”
c  = Push button position “Drain”
d = Drainage socket (led outside through floor of vehicle)

Opening the safety/drain valve

 

– Turn the rotary switch by 180° until it engages, whereby the 

push button pops out (position c). The water from the boiler 
will be released through the drainage socket (d).

The FrostControl drainage socket (d) must be free of contami-
nation (slush, ice, leaves, etc.) at all times so the water can 
drain out easily! 

There shall be no claims under guarantee 

for damage caused by frost!

Closing the safety/drain valve

 

– Check whether the rotary switch is set to “On” (position a), 

i.e. parallel to the water connection and engaged.

 

– Close the safety/drain valve by pressing the push button. 

The push button must engage in position (b) "closed". 

Only when the temperature at the safety/drain valve is above 
approx. 7 °C can it be closed manually with the push button 
(position b) and the boiler filled.

Truma supplies a heating element (part no. 70070-01) as an 
accessory, which is inserted into the FrostControl and fixed 
in place with a retaining bracket. This heating element heats 
Combi the FrostControl to approx. 10 °C when the Combi is 
switched on. This means that the boiler can be filled after a 
shorter time, irrespective of the temperature in the installation 
compartment.

Automatic opening of the safety/drain valve

If the temperature at the drain valve is below about 3 °C, it 
will open automatically and the push button pops out (posi-
tion c). The water from the boiler will be released through the 
drainage socket (d).

B. Safety/drain valve 

(Safety/drain valve without frost protection / 
standard in UK version)

The safety/drain valve automatically equalises the pressure in 
the event of overpressure in the system. When this occurs, 
the water is drained to the outside in intermittent bursts via a 
drainage socket.

This safety/drain valve does not protect the water 
container from 

frost damage.

c

b

a

d

Fig. 4

a  = Lever in position "Operational – closed“
b = Lever in position "Operational – closed“
c  = Lever in position "Drain"
d = Drainage socket (led outside through floor of vehicle)

Opening the safety/drain valve

 

– Move lever to position (c) - vertical. The water from the 

boiler drains through the drainage socket (d).

The drainage socket (d) of the safety/drain valve must be free 
of contamination (slush, ice, leaves, etc.) at all times so the 
water can drain out easily! 

There shall be no claims under 

guarantee for damage caused by frost!

Opening the safety/drain valve

 

– Move lever to position (a) or (b) - horizontal.

Operating instructions

Summary of Contents for Combi 2 CP plus ready

Page 1: ...he vehicle Mode d emploi Page 18 garder dans le v hicule Istruzioni per l uso Pagina 26 Da tenere nel veicolo Gebruiksaanwijzing Pagina 34 In het voertuig meenemen Brugsanvisning Side 42 Skal medbring...

Page 2: ...nis Verwendete Symbole 3 Verwendungszweck 3 Funktionsbeschreibung Combi 3 Funktionsbeschreibung Combi E 3 Sicherheitshinweise 4 Wichtige Bedienungshinweise 4 Gebrauchsanweisung Raumthermostat 5 Sicher...

Page 3: ...rd nur Warmwasser ben tigt ist dies im Warmwasserbetrieb m glich Bei Temperaturen von ca 3 C am automatischen Sicherheits Ablassventil FrostControl ffnet dieses und entleert den Boiler F r den Betrieb...

Page 4: ...rstaut werden da es hier unter Umst nden zu erh h ten Temperaturen kommen kann F r die Gasanlage d rfen nur Druckregeleinrichtungen gem EN 12864 in Fahrzeugen mit einem festen Ausgangsdruck von 30 mba...

Page 5: ...tutzen d des FrostControl muss stets frei von Verschmutzungen Schneematsch Eis Laub etc gehal ten werden um ein sicheres Ablaufen des Wassers zu ge w hrleisten Kein Garantieanspruch f r Frostsch den S...

Page 6: ...en Inbetriebnahme Der Gebrauch der installierten Bedienelemente analog digital ist jeweils in einer separaten Gebrauchsanwei sung beschrieben Combi CP plus ready Das Heizen des Innenraums ist je nach...

Page 7: ...s ca 60 C Boiler ca 20 Min gemessen nach EN 15033 Heizung Boiler ca 80 Min Pumpendruck max 2 8 bar Systemdruck max 4 5 bar Nennw rmeleistung automatische Leistungsstufen Gasbetrieb Combi 2 E 2000 W Co...

Page 8: ...icherheits Ablassventil schlie en Boiler l t sich nicht entlee ren obwohl das Sicherheits Ablassventil ge ffnet ist Entleerungsstutzen des Si cherheits Ablassventils ist verschlossen ffnung auf Versch...

Page 9: ...ummer des Ger tes sowie das Kaufdatum an Damit der Hersteller pr fen kann ob ein Garantiefall vorliegt ist durch den Endverbraucher das Ger t auf seine Gefahr zum Hersteller Servicepartner zu bringen...

Page 10: ...P plus ready 17 18 2 3 5 7 8 9 11 10 14 15 16 4 12 13 6 6 1 Fig 1 Table of contents Symbols used 11 Intended use 11 Function description Combi 11 Function description Combi E 11 Safety instructions 12...

Page 11: ...t water up at the same time If only hot water is required select hot water mode At a temperature of approximately 3 C at the automatic FrostControl safety drain valve the valve will open and drain the...

Page 12: ...subject to elevated temperatures Only pressure regulating equipment that complies with EN 12864 in vehicles with fixed output pressure of 30 mbar may be used for the gas system The flow rate of the p...

Page 13: ...t d The FrostControl drainage socket d must be free of contami nation slush ice leaves etc at all times so the water can drain out easily There shall be no claims under guarantee for damage caused by...

Page 14: ...by frost Start up The use of the installed control panels analogue digital is described in separate operating instructions Combi CP plus ready The interior can be heated either with or without water...

Page 15: ...s measured according to EN 15033 Heater boiler approx 80 min Pump pressure max 2 8 bar System pressure max 4 5 bar Rated thermal output automatic operating levels Gas mode Combi 2 E 2000 W Combi 4 E 2...

Page 16: ...y drain valve open Close safety drain valve Cannot empty boiler even though safety drain valve is open Safety drain valve draining connection blocked Inspect opening for contamination slush ice leaves...

Page 17: ...the factory number of the device and the purchase date In order for the manufacturer to be able to determine whether an incident subject to guarantee has occurred the end user must at his own risk bri...

Page 18: ...s ready 17 18 2 3 5 7 8 9 11 10 14 15 16 4 12 13 6 6 1 Figure 1 Table des mati res Symboles utilis s 19 Utilisation 19 Description du fonctionnement Combi 19 Description du fonctionnement Combi E 19 I...

Page 19: ...en mode hiver Mode de chauffage et de chauffe eau En mode de chauffage et de chauffe eau l appareil choisit automatiquement le palier de puissance requis en fonction de la diff rence entre la temp rat...

Page 20: ...r le fabricant de l installation Pour les v hicules nous conseillons l installation de d tente de gaz Truma MonoControl CS ainsi que les installations de d tente de gaz Truma DuoComfort DuoControl CS...

Page 21: ...ur assurer un coulement s r de l eau la tubulure de purge d du FrostControl doit toujours tre gard e exempte de salet s neige fondante glace feuilles mortes etc Nous d clinons toute garantie pour tout...

Page 22: ...sation des l ments de commande install s ana logique num rique est d crite dans un mode d emploi s par Combi CP plus ready Selon la position de fonctionnement le chauffage de l int rieur est possible...

Page 23: ...de chauffe d environ 15 C environ 60 C Chauffe eau env 20 min mesur selon EN 15033 Chauffage chauffe eau env 80 min Pression de pompe max 2 8 bar Pression de syst me max 4 5 bar Puissance de chauffage...

Page 24: ...ntation en eau Erreur Cause suppression Temps de chauffage extr mement long Entartrage de la cuve d eau D tartrer l installation d eau voir Maintenance L eau s coule impossible de remplir le chauffe e...

Page 25: ...la date d achat L utilisateur final doit amener ou exp dier l appareil ses risques au fabricant service apr s vente afin que le fabricant puisse v rifier le bien fond du recours sa garantie Envoyez ga...

Page 26: ...2 3 5 7 8 9 11 10 14 15 16 4 12 13 6 6 1 Figura 1 Indice Simboli utilizzati 27 Scopo d impiego 27 Descrizione del funzionamento Combi 27 Descrizione del funzionamento Combi E 27 Avvertenze di sicurez...

Page 27: ...odalit funzionamento ad acqua calda Quando la temperatura sulla valvola di scarico di sicurezza au tomatica FrostControl di circa 3 C essa si apre svuotando il boiler L apparecchio dispone di 3 modali...

Page 28: ...mpianto a gas utilizzare solamente regolatori di pressio ne conformi alla norma EN 12864 nei veicoli con pressione fissa in uscita di 30 mbar La portata del regolatore di pres sione deve soddisfare al...

Page 29: ...del FrostControl libero da impurit fanghiglia di neve ghiaccio fogliame ecc per garantire uno scarico dell acqua sicuro La garanzia non copre i danni dovuti al gelo Chiusura della valvola di scarico d...

Page 30: ...llati analogici digitali descritto rispettivamente in istruzioni per l uso separate Combi CP plus ready Il riscaldamento dell abitacolo in base alla posizione di funzionamento possibile sia con sia se...

Page 31: ...ntenuto acqua 10 litri Tempo di riscaldamento da 15 C circa a 60 C circa Boiler 20 min circa misurato conformemente alla norma EN 15033 Stufa e boiler circa 80 min Pressione della pompa max 2 8 bar Pr...

Page 32: ...ua Errore Causa rimedio Tempo di riscaldamento estremamente lungo Formazione di calcare nel ser batoio dell acqua Eliminare il calcare dall impianto idraulico vedere manutenzione L acqua scorre imposs...

Page 33: ...e il diritto alla garanzia il consumatore finale dovr farsi carico a proprio rischio del trasporto o della spedizione dell apparecchio pres so il costruttore stesso o un partner di assistenza In caso...

Page 34: ...17 18 2 3 5 7 8 9 11 10 14 15 16 4 12 13 6 6 1 Afbeelding 1 Inhoudsopgave Gebruikte symbolen 35 Gebruiksdoel 35 Functiebeschrijving Combi 35 Functiebeschrijving Combi E 35 Veiligheidsaanwijzingen 36 B...

Page 35: ...g is kan dit in de warmwaterstand Bij temperaturen van ca 3 C bij de automatische veiligheids aftapkraan FrostControl gaat deze open en wordt de boiler geleegd Voor de werking van het toestel heeft u...

Page 36: ...gen niet in de inbouwruimte van de kachel worden opgeslagen omdat er hier onder bepaalde omstan digheden hoge temperaturen kunnen optreden Voor de gasinstallaties mogen alleen drukregelinrichtingen vo...

Page 37: ...aftapaansluiting d weg De aftapaansluiting d van de FrostControl moet steeds vrij gehouden worden van verontreinigingen sneeuwblubber ijs bladeren etc om een goede afvoer van het water te garan deren...

Page 38: ...bedieningselementen analoog digitaal is steeds in een separate gebruiks aanwijzing beschreven Combi CP plus ready Het verwarmen van de binnenruimte is afhankelijk van de stand zowel met als zonder wat...

Page 39: ...warmtijd van ca 15 C tot ca 60 C Boiler ca 20 min gemeten volgens EN 15033 Kachel boiler ca 80 min Pompdruk max 2 8 bar Systeemdruk max 4 5 bar Nominale warmtevermogen automatische vermogensstanden Ga...

Page 40: ...aftapkraan is open Veiligheids aftapkraan sluiten Boiler kan niet worden ge leegd hoewel de veiligheids aftapkraan geopend is Aftapaansluiting van de veilig heids aftapklep is gesloten Opening contro...

Page 41: ...en te controleren of er sprake is van een garantieclaim moet de klant het toestel op eigen risico naar de fabrikant servicepartner brengen of opsturen Bij schade aan de warmtewisselaar moet de gebruik...

Page 42: ...y 17 18 2 3 5 7 8 9 11 10 14 15 16 4 12 13 6 6 1 Fig 1 Indholdsfortegnelse Anvendte symboler 43 Anvendelse 43 Funktionsbeskrivelse Combi 43 Funktionsbeskrivelse Combi E 43 Sikkerhedsanvisninger 44 Vig...

Page 43: ...r kun behov for varmt vand er dette muligt i varmtvandsdrift Ved temperaturer fra ca 3 C ved den automatiske sikker heds aftapningsventil FrostControl bner ventilen og t mmer vandvarmeren Til drift af...

Page 44: ...r iht EN 12864 i k ret jer kun anven des trykregulatorer med et fast udgangstryk p 30 mbar Tryk reguleringsanordningens gennemstr mningshastighed skal som minimum svare til maks forbruget for alle app...

Page 45: ...Aftapningsstudsen d p FrostControl skal altid holdes fri for snavs sne is l v etc s alt vandet kan l be ud Garantien d kker ikke frostskader Lukning af sikkerheds aftapningsventilen Kontroller at drej...

Page 46: ...tskader Ibrugtagning Brugen af de installerede betjeningselementer analog digital er beskrevet i en separat brugsanvisning Combi CP plus ready Opvarmningen af kabinen er afh ngig af driftspositionen b...

Page 47: ...t iht EN 15033 Varmeovn vandvarmer ca 80 min Pumpetryk maks 2 8 bar Systemtryk maks 4 5 bar M rkevarmekapacitet automatiske effekttrin Gasdrift Combi 2 E 2000 W Combi 4 E 2000 W 4000 W Combi 6 E 2000...

Page 48: ...fyldes op Sikkerheds aftapningsventilen er ben Luk sikkerheds aftapningsventilen Vandvarmeren t mmes ikke selvom sikkerheds aftap ningsventilen er ben Sikkerheds aftapningsventilens aftapningsstuds e...

Page 49: ...ugeren transportere eller sende apparatet til producenten servicepartneren for egen risiko Ved skader p varmeveksleren skal den anvendte gastrykregulator ogs indsendes Ved klimasystem For at undg tran...

Page 50: ...eady 17 18 2 3 5 7 8 9 11 10 14 15 16 4 12 13 6 6 1 Bild 1 Inneh llsf rteckning Anv nda symboler 51 Anv ndnings ndam l 51 Funktionsbeskrivning Combi 51 Funktionsbeskrivning Combi E 51 S kerhetsanvisni...

Page 51: ...Om enbart varmvatten beh vs st lls v rmaren in p varmvattendrift N r temperaturen p den automatiska s kerhets avtapp ningsventilen FrostControl ligger p ca 3 C ppnas denna och boilern t ms F r drift...

Page 52: ...ellt kan f rekomma h ga temperaturer h r F r gasolanl ggningen f r endast tryckregulatorer enligt EN 12864 i fordon med ett fast utg ngstryck p 30 mbar an v ndas Fl det genom tryckregulatorn m ste min...

Page 53: ...id h llas fri fr n smuts sn modd is l v etc f r att garantera problemfri avtappning av vattnet Garantin g ller inte f r frostskador St nga s kerhets avtappningsventilen Kontrollera att vridstr mst lla...

Page 54: ...av de installerade man verelementen analogt digitalt beskrivs i en separat bruksanvisning Combi CP plus ready Beroende p driftl get kan bodelen v rmas upp s v l med som utan vatteninneh ll Combi E CP...

Page 55: ...er ca 80 min Pumptryck max 2 8 bar Systemtryck max 4 5 bar Nominell v rmeeffekt automatiska effektniv er Gasoldrift Combi 2 E 2 000 W Combi 4 E 2 000 W 4 000 W Combi 6 E 2 000 W 4 000 W 6 000 W Eldrif...

Page 56: ...ppningsventilen r ppen St ng s kerhets avtappningsventilen Boilern kan inte t mmas trots att s kerhets avtapp ningsventilen har ppnats S kerhets avtappningsven tilens avtappningsstuts r blockerad Kont...

Page 57: ...slutanv ndaren p egen risk l mna eller skicka enheten till tillverkaren servicepartnern Vid skador p v rme v xlaren m ste den anv nda gastrycksregulatorn meds ndas F r klimatanl ggningar F r att undv...

Page 58: ......

Page 59: ......

Page 60: ...sninger om apparattype og fabriksnummer se typeskiltet klar for hurtig behandling Vid fel skall Truma servicecenter eller en av v ra auktoriserade servicepartners kontaktas se Truma serviceh fte eller...

Reviews: