________________________________________________________________________
11
10.3 Cleaning takes longer than there is space in the online data
A maximum of 90 min. online values can be recorded during a cleaning process.
If a cleaning takes more than 90 min. it will indicate that a RAM overflow has occurred and
that the online readings are not complete. In this case, the first 90 min. of the cleaning
were recorded. This only applies to online values. Cleaning continues normally.
11 Data transfer to LactoPro
The measured data can be analyzed in LactoPro.
This should be used with LactoPro version 6.0.90. This version can be obtained from
WMB or from the website:
www.wmb.ch/LCT-T/lactopro
11.1 Data on the USB stick
The measurement data from the LC T-T is displayed on the USB stick in the folder "LCS
measurement data". If this folder is not already available, the LC T-T will automatically
create one. The measurement data file is made up of the abbreviation MD for
measurement data, the operating number and the date when operating data was written to
the LCS. If no operating data has been used, 0 is entered.
e.g.: MD_1234567890123456_121115.DAT
MD:
Identification
for a measurement data file
1234567890123456: Operating number
121115:
On 12/11/2015 the operating data on the LC T-T
were loaded
11.2 Transferring data to the PC
The desired measurement data file must be copied manually in the LactoPro folder in the
following path:
".. "LactoPro\Daten\Datapack"LCS_Messdaten"
The LCS_Messdaten folder must be created manually once.
The program "LactoPro" can then be started. The reading of the LC T-T measurement
data is now the same as reading data from a data pack.
Under "Data- Telepack -> Measurement and Operating Data DP -->PC"
The LC T-T data can be viewed like the data from the LactoCorder in LactoPro.
The following values are currently stored correctly:
- Operating
number
- Animal number 2
- Bottle
ID
- Device
number
- Time
- Date
- Milking place number