________________________________________________________________________
8
7 Add the amount of the gap to the total quantity of milk?
It depends on the measurement procedure if the content of the sampling may be added on
the LC T-T for the total or not.
7.1
Milk quantity measurement and sampling at the same time
Where sampling and milk quantity measurement are carried out jointly, the
amount of milk split off from LC T-T may be added to the quantity of milk.
7.2
Checking the quantity of milk
The test of the quantity of milk may be carried out without sampling.
If the milk quantity measurement is carried out with sampling, usually the milk in the
sampler will be emptied in the bucket of the current milking. In this case,
the addition of the release quantity to the quantity of milk must be active.