   2.7   Safety 

 
      2.7.1 

 General 

 
 

     

   

The design of the LC T-T corresponds to the current state of 

        

technology 

and 

is 

reliable. 

 
 

     

   

The individual modules as well as the complete device are 

 

     

   

tested by our quality assurance. 

 
 

     

   

Only use the device when it is in perfect condition and in 

        

accordance 

with 

its 

intended purpose, consciously taking 

 

     

   

into account the operating instructions. 

 
        

Faults 

that 

may 

affect 

operational 

safety, 

        

eliminate 

immediately. 

 

      2.7.2  Special 

note 

 

        

Before 

commissioning 

the 

device, read the operating instructions 

        

carefully. 

 
        

Lack 

of 

knowledge 

about 

the operation and support of the system 

 

     

   

can cause damage to the LC T-T.   

 
        

Keep 

the 

operating 

instructions always at the place of use! 

 
        

Changes 

or 

modifications to the device are not permitted 

        

without 

the 

approval of the supplier.  

 
 

     

   

No program changes (software) to programmable 

        

control 

systems! 

 

 

     

2.7.3  Selection of operating personnel 

 
 

     

   

Work on the LC T-T may only be carried out by well-instructed 

        

personnel. 

 
        

Use 

only 

well-trained 

personnel. Regulate the responsibility 

        

of 

the 

staff 

for 

equipping, operating, maintenance, 

        

and 

repairing 

clearly. 

 

 

Summary of Contents for LactoCorder T-T

Page 1: ...___________________________________________ System LactoCorder T T Operating Manual Development and production WMB AG Wegenstrasse 6 CH 9436 Balgach Tel 41 0 71 727 18 30 Fax 41 0 71 727 18 31 E mail...

Page 2: ...rol 4 2 6 3 Transport damage 4 2 7 Safety 5 2 7 1 General 5 2 7 2 Special note 5 2 7 3 Selection of operating personnel 5 3 Test fluid for water tests 6 4 Setting up the LC T T in the stable 6 5 One t...

Page 3: ...ntion The device may only be used by persons familiar with the operating instructions and the applicable regulations on occupational safety and accident prevention 2 2 Uses Abbreviations LC T T LactoC...

Page 4: ...substance and non standard cleaning products not approved for milking machines 3 Separate mechanical or chemical cleaning of the probes e g brushes with abrasives or similar 4 Mechanical force effects...

Page 5: ...safely 2 6 2 Unpacking Entrance Control The shipping container for machines and equipment keeps normal stresses during transport on roads rails and in the air Before you put the device into operation...

Page 6: ...fety eliminate immediately 2 7 2 Special note Before commissioning the device read the operating instructions carefully Lack of knowledge about the operation and support of the system can cause damage...

Page 7: ...USB stick on the LC T T 5 3 In the main menu press the button 9 twice in quick succession It appears the password entry for the hidden service menu 5 4 Enter the six digits password complementary val...

Page 8: ...hted milk quantity 5 17 Press button 2 5 18 Switch to the next menu with ENTER Enter the sampling during online measurement 5 19 Press button 9 Enter sample 5 20 Press the 2 button Then press four tim...

Page 9: ...he same time Where sampling and milk quantity measurement are carried out jointly the amount of milk split off from LC T T may be added to the quantity of milk 7 2 Checking the quantity of milk The te...

Page 10: ...T has to be taken into account The storage level in the LC T T is always different at the end of a measurement This milk quantity difference that must be taken into account The LC T T measures the sto...

Page 11: ...Table 1 Battery capacity indicator 10 Possible errors and their solution 10 1 Error No filter inserted Measurement not possible without filter This error is displayed when starting up and starting th...

Page 12: ...T T will automatically create one The measurement data file is made up of the abbreviation MD for measurement data the operating number and the date when operating data was written to the LCS If no o...

Page 13: ...quantity Battery status 0 full 1 2 3 2 1 3 3 almost empty 4 empty Total milking Species 11 3 Write data to USB stick 11 3 1 Turn on LC T T 11 3 2 Insert the USB stick on the LC T T 11 3 3 Switch to th...

Reviews: