background image

12

Maintenance

SPECIFICATIONS

Maximum Surge Watts  . . . . . . . . . . . . . . . . . .8,550 watts
Continuous Wattage Capacity  . . . . . . . . . . . .5,550 watts
Power Factor  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0
Rated Maximum Continuous AC Load Current:

At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . .46.2 Amps
At 240 Volts . . . . . . . . . . . . . . . . . . . . . . . . .23.1 Amps

Phase  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . . 5 U.S. gallons
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . 169 lbs.

GENERAL MAINTENANCE

RECOMMENDATIONS

The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.

Should you have questions about replacing components on
your Troy-Bilt®  generator, please  call 1-888-611-6708 for
assistance.

Engine Maintenance

See engine owner’s manual for instructions.

KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.

NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.

Generator Cleaning

• Use a damp cloth to wipe exterior surfaces clean.

• Use a soft bristle brush to loosen caked on dirt or oil.

• Use a vacuum cleaner to pick up loose dirt and debris.

• Use low pressure air (not to exceed 25 psi) to blow away

dirt. Inspect cooling air slots and opening on generator.
These openings must be kept clean and unobstructed.

Data Tag

Data tag information is very important if you need help from
our Customer Service Department or an authorized service
dealer.

• The data tag (Figure 9) is located either on the heat shield

or engine support on the muffler side of the generator.
For future reference, please copy the model, revision, and
serial number of the generator in the space below.

5

Section

MODEL

REV NO

SERIAL

AC VOLTS

AC AMPS

AC WATTS

DC VOLTS

DC AMPS

Figure 9 — Data Tag

Copy Model

Number Here

Copy Revision

Here

Copy Serial

Number Here

• Used motor oil has been shown to cause skin cancer in

certain laboratory animals.

• Thoroughly wash exposed areas with soap and water.

Avoid prolonged or repeated skin contact with used
motor oil.

CAUTION

• DO NOT expose generator to excessive moisture, dust, dirt,

or corrosive vapors.

• DO NOT insert any objects through cooling slots.

Improper treatment of generator can damage it and
shorten its life.

CAUTION

Summary of Contents for 1919

Page 1: ...F 8 5 CT Troy Bilt is a registered trademark of Troy Bilt LLC and is used under license to Briggs Stratton Power Products Troy Bilt es una marca registrada registrada de Troy Bilt LLC y se usa abajo l...

Page 2: ...ES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death The safety alert symb...

Page 3: ...cigarette or smoke WHEN STARTING EQUIPMENT Ensure spark plug muffler fuel cap and air cleaner are in place DO NOT crank engine with spark plug removed If fuel spills wait until it evaporates before st...

Page 4: ...rical output is lost equipment sparks smokes or emits flames unit vibrates excessively Improper treatment of generator can damage it and shorten its life CAUTION WHEN ADJUSTING OR MAKING REPAIRS TOYOU...

Page 5: ...ng for assistance Fuel Tank Capacity of five 5 U S gallons Grounding Fastener If required please consult a qualified electrician electrical inspector or local agency having jurisdiction Oil Fill Add e...

Page 6: ...from shipping carton Install Wheel Kit The wheel kit is designed to greatly improve the portability of your generator NOTE Wheel kit is not intended for over the road use You will need a socket wrenc...

Page 7: ...e bearing Add Fuel NOTE This gasoline engine is certified to operate on gasoline Exhaust Emission Control System EM Engine Modifications 1 Use clean fresh regular UNLEADED fuel with a minimum of 85 oc...

Page 8: ...exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other openings that can al...

Page 9: ...al 4 Move fuel valve to Off position Figure 4 Fuel Valve Off Position On Position See Don t Overload Generator Start generator and let engine stabilize before connecting electrical loads Connect elect...

Page 10: ...ds at 20 Amps or greater GENERATOR ADAPTER CORD SET The generator is equipped with a 25 generator adapter cord set designed for a 240Volt 30 Amp grounded neutral circuit Figure 7 The generator adapter...

Page 11: ...ngine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more l...

Page 12: ...f water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator winding insulation Water and dirt buildup on the generator internal wi...

Page 13: ...orming in fuel system or on essential carburetor parts add fuel stabilizer into fuel tank and fill with fresh fuel Run the unit for several minutes to circulate the additive through the carburetor The...

Page 14: ...in good condition 4 Contact Authorized Service Facility When loads are connected engine runs good but bogs down 1 Short circuit in a connected load 2 Generator is overloaded 3 Engine speed is too slo...

Page 15: ...ts performance and reliability This warranty also does not cover normal maintenance such as adjustments fuel system cleaning and obstruction due to chemical dirt carbon or lime etc Other Exclusions Al...

Page 16: ...informaci n acerca de la garant a consulte con el manual del propietario del motor REGLAS DE SEGURIDAD ste es el s mbolo de alerta de seguridad Sirve para advertir al usuario de un posible riesgo para...

Page 17: ...n causar quemaduras severas e inclusive la muerte ADVERTENCIA Opere el generador SOLAMENTE al aire libre Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ven...

Page 18: ...r Apague el generador si Se pierde la salida el ctrica El equipo produce chispas humo o emite llamas La unidad vibra de una manera excesiva El tratamiento inadecuado del generador puede da arlo y acor...

Page 19: ...ispas El silenciador disminuye el ruido del motor y est equipado con una pantalla apagachispas Tanque del Combustible El tanque tiene una capacidad de 5 galones americanos de gasolina sin contenido de...

Page 20: ...Saque el generador de la caja de env o Instale el Juego de Ruedas El juego de ruedas est dise ado para mejorar el transporte del generador NOTA Este Juego de Ruedas no ha sido dise ado para ser usado...

Page 21: ...onar con gasolina Sistema de control de emisiones de gases de escape EM Modificaciones del motor 1 Utilice combustible normal sin plomo limpia y nueva con un m nimo de 85 octanos NO utilice combustibl...

Page 22: ...pado Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio cerrado en el que puedan acumularse Figura 12 Tenga en cuen...

Page 23: ...ra 13 V lvula de Combustible Off Posici n On Posici n Vea No sobrecargue generador Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el ctricas Conecte las cargas el...

Page 24: ...con un Juego de Cables del Adaptador del Generador de 25 pies dise ado para un circuito neutro a tierra de 240 voltios 30 Amperios Figura 16 El juego de cables del adaptador del generador provee un s...

Page 25: ...mo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA a ada m s carg...

Page 26: ...ranuras para aire de enfriamiento algo del agua quedar retenida en los espacios vac os y grietas del aislamiento del devanado del estator y rotor La acumulaci n de agua y suciedad en los devanados int...

Page 27: ...on antes Reemplace la caneca de gasolina si comienza a oxidarse El xido y o la suciedad en la gasolina le causar problemas Almacene la unidad en un rea limpia y seca Almacenamiento Diagnosticos de Ave...

Page 28: ...ilidad Esta garant a tambi n no cubre el mantenimiento normal tales como ajustes limpieza del sistema de combusti n y la obstrucci n debido a materias qu micas suciedad carb n o cal etc Otras exclusio...

Reviews: