8.8.1
Installation and commissioning
1. A working table must be mounted and positioned at the
lowest position.
The laser machine must be switched off.
2. Place the rotary attachment onto the working table using the
existing insertion handles.
3. Position the rotary attachment so that the brackets of the
rotary snap to the ruler correctly.
4. Connect the connection cable of the rotary attachment to the
connector on the left front side of the housing.