![Trotec Speedy 360 flexx Operation Manual Download Page 67](http://html1.mh-extra.com/html/trotec/speedy-360-flexx/speedy-360-flexx_operation-manual_1172301067.webp)
Speedy 360
BA 8032_2.2_EN (05/2016)
67 / 90
www.troteclaser.com
8.7.3
Light bar focus
1. Make sure that the lens that is installed in the laser head is
selected in the JobControl
®
software.
2. Press the two keys for Z positioning (1) simultaneously for the
table to move up.
3. As soon as the previously loaded material passes the light
barriers, the upward movement of the table stops, and the table
moves to the correct focus position.
Focusing is then complete, and you can start the laser
processing.
The light barrier autofocus is ideal for flat opaque materials of unknown thickness.
This autofocus option will not work on transparent, rough or very thin material, which is
thinner as the ruler itself.
8.7.4
Sonar Technology™
1. Make sure that the lens that is installed in the laser head is
selected in the JobControl
®
software.
2. By simultaneous pressing of the two keys for Z positioning of
the table, the laser beam gets automatically focused on the
workpiece.
Focusing is then complete, and you can start the laser processing.
This focusing mode is especially well-suited for all sound-reflective materials.
1
1