7.2
Operating environment
Installation side requirements:
Operating conditions:
Operating temperature:
+15 °C to 25 °C (59 °F to 77 °F)
Air humidity:
40%
– 70% (non-condensing)
Provide sufficient illumination at the workplace.
Ensure a dust-free environment (II° according to IEC60947-1)
Uniform, level, horizontal and firm floor, planarity ±5 mm (±0.1969 inch), no special foundation
required.
Load-bearing capacity of base frame at least 300 kg/m2 (62 lbs./sq.ft.).
Freedom of interfering electrical installations, hoses and pipe lines
Power supply free of fluctuations
Shielding from EMC