insulation drying unit Qube+

Technical data and equipment

Qube+

TTKwic operating mode

Height-adjustable telescopic push handle

Cable holder with fixable plug

Thermal protection

Maintenance quick release fasteners

1

 maximum air flow rate of the fan motor (not integrated) 

2

 vvia Optiflow NT multi-function display 

3

 

What does MID-compliant mean?

 In some areas, the Measuring Instruments Directive (MID)

replaces the previous regulation of national authorization and subsequent calibration. As a result, all energy meters in Europe used for energy consumption-based billing have to be MID-compliant
from now on. Therefore, the Qube+ holds a separate certified, MID-compliant counter, which transmits its data to the Optiflow NT multi-function display for inspection.

Summary of Contents for Qube+

Page 1: ...TRT BA QUBE TC2015 27 010 EN QUBE EN ORIGINAL INSTRUCTIONS INSULATION DRYING UNIT ...

Page 2: ...ormity via the following link Qube https hub trotec com id 40717 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Do not use the device in potentially explosive rooms Do not use the device in aggressive atmosphere Set the device up in an upright and stable position Make sure that the air inlet a...

Page 3: ... Warning Small objects and particles can be sucked in and lead to injuries Make sure that no person is standing near the inlet or outlet opening while the device is running Warning Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way Observe the personnel qualifications Warning Risk of suffocation Do not leave the packaging lying around Children ...

Page 4: ... for discharge of hot process air Service socket tamper proof Cable holder Key lock to prevent maloperation ECO level stage 1 for small surfaces Height adjustable telescopic push handle The device is equipped with a touch screen with LC display It provides information on the operating stage air flow rate etc The background colour of the LC display changes according to the traffic light principle t...

Page 5: ...parking brake 10 Residual water draining button 11 Hose connectors 12 DA 4 sensor connection 13 Power button and communication port 14 Touchscreen control panel 15 Castor retainer for storage 16 Power cable retainer 17 Carrying handle upper part 18 19 21 22 20 23 No Designation 18 Connection for discharge of process air 19 Connector 50 mm 20 Service socket tamper proof 21 Holder for storage with r...

Page 6: ... 32 33 29 35 No Designation 23 F7 air filter 24 Air filter cover 25 F8 filter sleeve for HEPA filter optional 26 HEPA filter optional 27 Pump 28 Coarse filter 29 Coarse filter fixation grid 30 Demister holder 31 Demister 32 Wing nut 33 Cage 34 G4 filter sleeve 35 Spring contacts for electrical connection ...

Page 7: ...mponents Prior to every transport check whether the upper and lower part of the device are firmly connected via the tension locks Do not incline the device by more than 45 for otherwise the device could be damaged Storage Before storing the device proceed as follows Empty and clean the condensation tank prior to storage Hold onto the mains plug while pulling the power cable out of the mains socket...

Page 8: ...sories Art no 38 mm connector 7 200 000 002 HEPA filter module H13 high efficiency particulate air filter as per DIN EN 1822 1 filtration efficiency 99 97 0 3 µm incl F8 prefilter sleeve DIN EN 779 7 160 000 221 F8 filter sleeve for HEPA filter module filter class 8 DIN EN 779 7 160 000 215 F8 filter sleeve 7 160 000 216 connection cable VX DA for data transmission to the DA 4 7 333 000 015 sound ...

Page 9: ...the water discharge connection 2 Guide the other hose end to a drain or collection container Regularly inspect the drain hose and hose connection for kinks and dirt Remove kinks and clean the drain hose if required TTKwic quick couplings As standard the device comes with two integrated TTKwic quick couplings 7 where condensate discharge hoses of up to two used dehumidifiers plus condensate pump ca...

Page 10: ...installation Remove the sealing caps from the connectors to which you want to connect a hose If a connector is not needed the sealing cap must remain on the connector Note Connectors without a sealing cap or a connected hose may cause water to escape and thus result in water damages Carefully check the connectors before switching the device on For drying operations only use cables and sockets comp...

Page 11: ...thus reducing the noise emission e g at night Whisper mode is automatically left after 10 h and the compressor starts to run at its previously chosen power stage again Selecting another stage via the control panel will also stop the whisper mode Press the whisper mode button 40 to activate or deactivate whisper mode A countdown 10 h on the control panel indicates the remaining whisper mode duratio...

Page 12: ...e determined Info If a load is connected to the service socket its energy consumption will also be measured by the energy meter Connecting the DA 4 external control unit The communication port 41 is used for data transfer to the DA 4 control unit The data may then be forwarded USB and modem or USB only Additionally the internal sensor of the DA 4 must be connected via the sensor connection 12 Empt...

Page 13: ...ary Motor is not running Check the display If Behaelter getrennt is indicated the upper part may not be correctly positioned on the lower part Check whether the upper and lower part are properly connected to one another Check whether voltage is applied Check the electrical connections and safety installations Motor switches off during operation or its performance is reduced The device has been ove...

Page 14: ...much water in the insulation layer or an unconnected drain hose causes the pump to operate continuously Check the drain hose for proper fit There must be no kinks or loops in the hose that could prevent the water from being drained off Check for potential leakage Fault message Cause Remedy abpumpen pumping off The pump drains the accumulated water No action required If the pump is to run permanent...

Page 15: ...rocess https www youtube com watch v 8_G8kCDMHIM Cleaning the housing Clean the device with a soft damp and lint free cloth Ensure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Draining residual water The residual water should always be...

Page 16: ...s it does not allow a sufficient quantity of air to pass Observe the following before cleaning or replacing the filter Press the power button 42 to switch the device off Disconnect the device from the mains Drain the residual water from the tank The device is equipped with different filter types G4 filter sleeve 34 F8 filter sleeve also an option here F8 filter sleeve for HEPA filter optional 25 H...

Page 17: ...eplacing the G4 filter sleeve If the Filter wechseln message appears on the display the G4 filter sleeve inside the device must be replaced as it does not allow a sufficient quantity of air to pass ü The device is switched off and disconnected from the mains ü The residual water has been drained 1 Open the 4 tension locks 4 2 Lift the upper part at the carrying handle 17 and place it onto a stable...

Page 18: ... locks Cleaning the demister ü The device is switched off and disconnected from the mains ü The residual water has been drained ü The upper part has been removed see Replacing the G4 filter sleeve 1 Take the demister out of the holder in the lower part of the device 2 Rinse the demister under running water ð Exchange the demister if required e g in case of damages 3 Put the demister back into the ...

Page 19: ...uick coupling of the hose 43 on the tank wall 5 Slightly lift the sheet that is fixating the pump 6 Take out the pump 7 Detach the pump filter from the pump 8 Rinse the pump filter under running water ð Exchange the pump filter if required e g in case of damages 9 Slightly lift the sheet that is fixating the pump and refit the pump 10 Check the pump for tight fit 11 Plug the hose 43 back into the ...

Page 20: ...al connection and put the plug 44 back in 11 Refit the coarse filter fixation The coarse filter fixation should rest on the coarse filter 12 Refit the demister along with the holder 13 Put the upper part back on the device and close the tension locks Replacing the G4 filter sleeve by an F8 filter sleeve optional If a finer ambient air filtration is required the G4 filter sleeve can be replaced by ...

Page 21: ... display during operation you can exchange the F8 filter sleeve in a first step If this is not sufficient Filter wechseln message still displayed the HEPA filter must be exchanged as well ü The device is switched off and disconnected from the mains ü The residual water has been drained 1 Please proceed as described in steps 1 and 2 in the chapter Replacing the G4 filter sleeve 2 Turn the upper par...

Page 22: ...dB A Volume collection container 10 l Input voltage 230 V 50 Hz Weight 27 kg Dimensions L x W x H telescopic push handle down up 490 x 500 x 735 925 mm Mobility carrying handle stackable rollable carriage design Hose connections insulation drying 3 x ø 38 mm TTKwic dehumidifier quick couplings 2 x Waste water connection DA 4 interface Efidry humidity sensor connection Service socket tamper proof 5...

Page 23: ...via Optiflow NT multi function display 3 What does MID compliant mean In some areas the Measuring Instruments Directive MID replaces the previous regulation of national authorization and subsequent calibration As a result all energy meters in Europe used for energy consumption based billing have to be MID compliant from now on Therefore the Qube holds a separate certified MID compliant counter whi...

Page 24: ...ying unit Qube Exploded assembly drawing Info The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions A B 2 3 4 1 11 12 7 13 6 8 9 10 5 14 15 16 ...

Page 25: ...m 6 P10003459 housing Qube filter insert 7 7 160 000 221 HEPA filter module H13 incl F8 prefilter sleeve 8 P10000203 demister insert 9 P10002223 housing Qube demister holder 10 P10006736 Qube water separator bottom filter mat 11 7 160 000 213 F7 Z line filter 12 P10003460 housing Qube cover air aperture 13 7 160 000 214 G4 filter sleeve 14 7 331 000 476 drain hose 5 m 15 7 170 001 201 pump with pl...

Page 26: ...contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 40717 Declaration of conformity In accordance with the EC Machinery Directive 2006 42 EC Annex II part 1 Section A Herewith we Trotec GmbH Co KG declare that the machinery designated below was developed constructed and produced in compliance with the requirements of the EC Machine...

Page 27: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: