EN
15
insulation drying unit Qube+
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Note
Observe the overvoltage protection.
The device comes equipped with an overvoltage
protection. When checking for electrical safety, please
bear in mind that the test voltage has to be reduced to
250 V.
Info
Via the following link you will find an explanation of
how to clean the Qube+ and what to observe for this
process:
https://www.youtube.com/watch?v=8_G8kCDMHIM
Cleaning the housing
Clean the device with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Draining residual water
The residual water should always be drained before the device
is transported.
Press the button for residual water draining to drain the water
left in the tank.
Exchanging or removing the drain hose
The drain hose should be cleaned if dirt is visible.
If there are signs of wear or damage, the drain hose should be
exchanged.
Remove the drain hose before transporting the device.
ü
The device is switched off and disconnected from the
mains.
ü
The residual water has been drained.
1. Press the blue ring on the outside of the quick coupling
together and at the same time pull the hose.