insulation drying unit Qube+
Positioning the device
When setting up the device, make sure that the warm air
generated by the device is discharged. The room temperature
should not exceed 35 °C.
If condenser dryers are operated at temperatures above 35 °C
and at high humidity levels permanently, the pressure in the
refrigerant circuit will rise. Consequently the compressor will
permanently run at its limit, which leads to increased wear and
tear.
•
If required, ensure that the process air is discharged by
connecting a suitable discharge hose to the process air
discharge connection (18).
•
Provide sufficient fresh air supply by ventilating the room
at regular intervals.
•
Should the discharge of warm air not be an option, the
device can also be installed outside of the room to be dried
and the hose connection can be established by means of a
PlanoPro door gap nozzle (art. no. 6.100.000.160).
Such an installation may look like this, for example:
The device comes equipped with an overheating protection.
This serves to prevent excessive ambient temperatures.
It protects the materials and devices located in the room.
Start-up
•
Use suitable hoses (observe number and diameter) to set
up the drying installation.
•
Remove the sealing caps from the connectors to which you
want to connect a hose. If a connector is not needed, the
sealing cap must remain on the connector.
Note
Connectors
without
a sealing cap or a connected hose
may cause water to escape and thus result in water
damages.
Carefully check the connectors before switching the
device on.
•
For drying operations, only use cables and sockets
complying with the regulations. In addition to the 16 A
fuse, the socket should also be secured by a 30 mA
residual current device (RCD).
Note
We recommend using a suitable mat if the Qube is
placed on sensitive ground.
Inserting the filters
Check whether the filters have been properly inserted into the
device:
•
G4 filter sleeve or optional F8 filter sleeve or HEPA filter
with F8 filter sleeve
•
demister
•
coarse filter (filter mat) with coarse filter fixation
•
pump filter
Info
The coarse filter fixation should rest on the coarse filter
to prevent the coarse filter from floating
unintentionally.
Mains connection
•
Plug the mains plug into a sufficiently fused socket.
Switching the device on
Press the power button (42) to switch the device on.
The following working stages are available:
•
4 power stages 1-4
•
stage 5: boost stage
•
whisper mode
•
TTKwic mode
Check the installation via the LC display:
•
green: optimal air volume flow
•
yellow: limit range
•
red: air flow rate too low – installation must be optimized