TROOPER : Negative Pressure System
will cause a temporary high suction that may draw out
coolant if the TROOPER is not adjusted for a high enough
vacuum. In these cases, of course the tool must be in
production before a final adjustment can be made.
2.
In extreme cases, it may be necessary to shut the flow off
just prior to the mold opening to eliminate any leakage. This
can be done by installing a solenoid on the ‘TO MOLD’ line
that is closed by one of several methods: the clamp open
signal from the molding press, or a cycle timer, or a parting
switch between mold halves. The most effective signalling
method will depend upon the type of cavity leak. For free
consultation call ADVANTAGE ENGINEERING, INC. at
317-887-0729.
ILLUSTRATIVE PART WHICH WILL
DRAW OUT COOLANT UPON
EJECTION
4.6 USING ADVANTAGE TROOPER AS A BOOSTER PUMP