TROOPER : Negative Pressure System
are off during normal operation.
B.
Pressure switches on all ADVANTAGE TROOPER units are preset
to prevent pump damage and extend the life of the unit. DO NOT
ADJUST OR DISABLE PRESSURE SWITCHES.
C.
‘SUPPLY PRESSURE TOO LOW’: this indicator light will come on
when the unit has shut down because the supply pressure is less
than 8 PSI. All ADVANTAGE TROOPER units have a low pressure
shut off switch connected to the supply plumbing to prevent the
pump from being damaged by running dry.
D.
‘DRAIN PRESSURE TOO HIGH’: this indicator light will come on
when the unit has shut down because the drain pressure is greater
than the pumping capacity of the unit. The high pressure shut off
switch protects the motor from being damage by excessive strain.
E.
FOR ADDITIONAL INFORMATION OR PROBLEM SOLVING
REFER TO THE TROUBLESHOOTING GUIDE.
3.4 SHUT DOWN & STORAGE
A.
The following instructions are silk-screened on the top of the unit for
easy reference.
B.
Step 1: shut off “TO MOLD’ line.
C.
Step 2: To purge mold completely, allow air to enter ‘TO MOLD’
hose until all water is out.
D.
Step 3: Shut off ‘FROM MOLD’ line.
E.
Step 4: Turn off unit.
F.
Step 5: Shut off ‘SUPPLY’ line.
G.
Step 6: Shut off “DRAIN’ line.
H.
Step 7: Drain unit for storage.
I.
It is important to drain the unit when no in use for extended periods.
This will prevent sediments and mineral deposits from building up
inside the pump and causing damage.