TROOPER : Negative Pressure System
OVERLOAD CHART
MODEL
TR-100
TR-200
TR-300
TR400
TR500
PHASE
1
1
3
3
1
1
3
3
1
1
3
3
3
3
3
3
VOLTAGE
110v
220v
220v
440v
110v
220v
220v
440v
110v
220v
220v
440v
220v
440v
220v
440v
OVERLOAD
8.0 - 12.3
4.0 - 6.3
1.8 - 2.8
0.8 - 1.2
8.0 - 12.3
4.0 - 6.3
1.8 - 2.8
0.8 - 1.2
8.0 - 12.3
4.0 - 6.3
2.8 - 4.0
1.8 - 2.8
2.8 - 4.0
1/8 - 2.8
5.6 - 8.0
2.8 - 4.0
PART #
E OL8-12.3
E OL4-6.3
E OL1.8-2.8
E OL8-12
E OL8-12.3
E OL4-6.3
E OL1.8-2.8
E OL8-12
E OL8-12.3
E OL4-6.3
E OL2.8-4
E OL1.8-2.8
E OL2.8-4
E OL1.8-2.8
E OL6-9
E OL2.8-4
PHASE MONITOR
VOLTAGE
220V
380V
440V
PHASE MONITOR
SLA-220-ASA
SLA-380-ASA
SLA-440-ASA
PART #
E REV-RLY220
E REV-RLY380
E REV-RLY440
C.
To change the voltage:
1.
Replace motor overload with correct one for the new
voltage, see chart below. Refer to appendix “Overload
Setting and Resetting” for proper adjustment procedures.
2.
Replace the phase monitor with correct one for the new
voltage, see chart below. Refer the section 1.B “Checking
the phase monitor “ for proper adjustment procedures.
3.
Change the jumper connections on the primary side of the
transformer as indicated on the transformer.
4.
Change the wiring on the motor as per the diagram on the
motor plate.
5.
Replace the voltage sticker labels to indicate the new
voltage. This is an important step to help prevent incorrect
power connections.
D.
Replacement overloads and phase monitors are available from
ADVANTAGE ENGINEERING, INC service department at 317-887-
0729. Transformers jumpers and voltage stickers will be supplied
free of charge, but must be requested when placing an order.