LC Display Messages (continued)
–
The individual lines of the display show: Date and time of the occurrence of the event
–
Description of the event
–
Program number of the event and predetermined code, for example
E = status message
* = fault message
R = fault message cancelled with “Reset“ push button
A = time of acknowledgement of the fault message
NOTE: Operating data displayed with the “UP arrow“ or “DOWN arrow” push buttons, remains
displayed for several minutes if no other push button is pressed. The display then
switches back to the standard converter parameters.
“Shift“ + “down arrow“ push buttons
The main setup menu is displayed by pressing the “Input” function buttons
(“Shift” and “down arrow” buttons simultaneously).
Pressing the “Down” button scrolls downwards through the main setup
menu.
Pressing the “Up” button scrolls upwards through the main setup menu.
A sub-menu is displayed by pressing the “Input function” buttons (“Shift”
and “down arrow” buttons simultaneously).
When numbers or letters are to be entered in the input fields of a sub-
menu, the desired entry is reached by scrolling using the “Up” and
“Down” buttons.
Most sub-menus have several input fields. Press the “Input” function
buttons to go from one input field to the next one. An active input field in
which entries can be made is indicated by the cursor.
With input fields allowing a choice between two items, for example,
yes/no or on/off, you can toggle between the various options by means
of the “Down” and “Up” buttons.
NOTE: When the last input field is reached in a sub-menu, the cursor
returns to the first input field when the “Input“ buttons are next
pressed.
Pressing the “Output“ function buttons (“Shift” and “up arrow” buttons
simultaneously) quits the sub-menu and displays the main menu. The
previous changes are accepted by the system at the same time.
Pressing the “Output“ button again quits the main setup menu and the