28.5 VDC Ground Power Unit
Models:
11A6647-1000/1010
11B6647-1000/1010
11C6647-1000/1010
11D6647-1000/1010
11A6647C1000/1010
11B6647C1000/1010
11C6647C1000/1010
11D6647C1000/1010
11A6655-1000/1020
11B6655-1000/1020
11C6655-1000/1020
11A6655C1000/1020
11B6655C1000/1020
11C6655C1000/1020
11D6655C1000/1020
11A6665-1000/1010
11B6665-1000/1010
11C6665-1000/1010
11A6666-1000
11B6666-1000
11C6666-1000
12/2006 - Rev. 04
- 35 -
5.3.4
LC Display Messages (continued)
The following sub-menus can be called up in the main menu:
•
Language
•
Contrast
•
Date/time
•
•
Type
•
Set-up
•
Password
•
Output voltage DC
•
Output current DC
•
Compensation DC
•
DSO Status
•
Remote control
Language
Set the language in which the display is to appear. Two languages are available.
Contrast
This menu allows you to set the contrast of the display.
Date/Time
Set the current date and time if required and then specify that the modified value should be
accepted.
Print
With this button the printout of all stored events can be started, as well as the status, if a serial
printer and link converter is connected to the A100 Control Board DB-9 connector.
Type
The type designation of the unit is set at the factory.
Set-Up
This menu transfers any changes in the setup to battery backed RAM. See DSO Status below.
Password
An appropriate password must be used in order to change settings in the following menus. In this
case please consult your Tronair representative.
Input Voltage
The unit can be operated with various input voltages and frequencies. This menu allows you to
set the right input voltage.
Output Voltage DC
This menu allows you to set the output voltage of the DC output.
Output Current DC
With this button the DC output current can be adjusted/limited. The adjustment range is either
unlimited or 8% to 100% of the nominal current. The normal adjustment is unlimited.
Output Voltage Compensation DC
This menu allows you to set the output voltage compensation factor (I-Boost) for the DC output.
DSO Status
A digital storage oscilloscope (DSO) function is built into the controller board. The status of the
DSO can be checked with this menu (for service personnel only).
Remote Control
Specify whether the buttons are to be enabled (input: 1) or blocked (input: 0) for a connected
Remote Control Panel (RCP).