DC7000 ANTIQUE

7

115 mm

pipe centres

Cold water supply

Hot water supply

Thermostatic

assembly

On/off

assembly

Swivel inlet

(Do not tighten

against body)

Mixed water

outlet

INSTALLATION

a) General conditions

NOTE: The outlet of the shower must not be
connected to any tap or fitting not
recommended by Triton Plc.

DO NOT use jointing compounds on any pipe
fittings for the installation.

Use only the compression fittings supplied. DO
NOT solder fittings within the vicinity of the
valve unit as heat transfer can damage the seals
and thermostatic components.

NOTE: Suitable isolating valves (complying with
Water Regulation Byelaws) MUST be fitted on
the hot and cold water supplies to the shower
as an independent means of isolating the water
supplies should maintenance or servicing be
necessary.

When connecting pipework avoid using tight
90° elbows. Swept or formed bends will ensure
optimum performance.

The valve unit can be fitted in any orientation
(fig.7), but for a wall mounted sprayhead
installation, the plumbing will be simplified if
the outlet is fitted upwards. Access to the
integral strainers will also be improved with this
configuration.

The hot water inlet is identified with a red mark,
the cold water inlet with a blue mark. The
swivel inlets allow for either rising or falling hot
and cold water supplies. Note the swivel inlets
have ‘O’ seals to the body and do not require
PTFE tape or other means of sealing.

Gently screw the swivel inlets into the body of
the valve unit and stop as soon as resistance is
felt. Then back off by up to 1.5 turns to align
the inlet with the hot and cold supply pipes.
THE SWIVEL INLETS MUST NOT BE TIGHTENED
AGAINST THE VALVE BODY TO MAKE A SEAL
(fig.8).

The Triton dual control mixer valve includes a
mounting bracket which allows the installer to
mount the shower into a solid, stud partition or
other hollow wall structures. The bracket can
also be used for fitting in a shower cubicle or
panel providing the back of the cubicle or panel
is accessible.

Fig.8

H

H

H

Outlet

C

C

C

H

Outlet

Outlet

Outlet

C

Fig.7

Summary of Contents for DC7000 Antique

Page 1: ...O L D O N O F F T R ITON SHOW E R S Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180290B May 2000 DC7000 dual control Antique mixer...

Page 2: ...DC7000 ANTIQUE UKAS QUALITY MANAGEMENT 003...

Page 3: ...wer 6 Installation general 7 8 Installation solid wall 9 hollow wall 10 cubicle or panel 11 Connecting the supply pipes 12 Fitting Showerhead 13 Using the tiling shroud 14 Fitting the face plate and k...

Page 4: ...en flowrate adjustments are made The valve unit can be fitted in any orientation For a wall mounted sprayhead installation the plumbing will be simplified if the outlet is fitted upwards The valve is...

Page 5: ...knob 4 On off control knob 5 Tiling shroud 6 Mounting bracket 7 Flat bracket 2 off 8 Sprayhead and arm 9 Tool and screw pack 10 Ceramic on off cap 11 Ceramic temperature cap 12 Trim rings 13 Flow lim...

Page 6: ...ply pipework can provide nominally equal pressures at the mixer valve For optimum performance of this shower both hot and cold water supplies to the shower valve should be fed at nominally equal press...

Page 7: ...us water heater the appliance must be capable of raising the temperature of the incoming water by 45 C 81 F and delivering a flow rate of not less than 8 litres per minute A flow limiter is supplied f...

Page 8: ...time when it is being installed The hot and cold water pipes should not be permanently attached to the wall closer than 2m from the valve prior to installation to allow for final adjustment of the va...

Page 9: ...tted in any orientation fig 7 but for a wall mounted sprayhead installation the plumbing will be simplified if the outlet is fitted upwards Access to the integral strainers will also be improved with...

Page 10: ...65 mm fig 9 measured from the face of the wall upon which the mounting bracket is screwed excluding the tile thickness The allowance for varying thickness of tiles up to 10mm is accommodated by a limi...

Page 11: ...when the installation is complete There is limited tolerance between the control knobs and trim rings to allow for varying thickness of tiles up to 10mm As a guide for the size of hole place the tilin...

Page 12: ...ying thickness of tiles up to 10mm Mark the route of the incoming and outgoing pipework As a guide for the size of hole place the tile shroud on the wall and trace around it fig 11 Take out the plaste...

Page 13: ...of the panel or cubicle Use the supplied template as a guide fig 16 After cutting the two holes fit the valve to the mounting bracket and secure using the four screws provided Offer the valve and mou...

Page 14: ...other sealing means is required Tighten the compression fittings with the cranked spanner supplied for when access is restricted Ensure the on off assembly is turned to the off position by temporarily...

Page 15: ...oles fig 21 Drill and plug the holes using the plugs supplied NOTE If fitting to a hollow wall structure use suitable cavity wall fixtures Apply PTFE tape to the 1 2 BSP thread on the shower head arm...

Page 16: ...nsuring the indicator notch is in the 12 o clock position It must be in this position regardless in which orientation the unit is mounted Secure by screwing on the two brass face plate retaining rings...

Page 17: ...e that should the knobs and faceplate require cleaning then care must be taken not to scratch them in the process Wash away any surface dust before cleaning with soapy water DO NOT USE ABRASIVE CLEANE...

Page 18: ...an uncontrolled manner then the hot and cold supplies are probably reversed This must be corrected before proceeding further The mixer valve is factory set to provide a maximum outlet temperature of...

Page 19: ...omer Service In domestic installations where D08 specification is not required the maximum temperature setting should not exceed 45 C OPERATING THE SHOWER To start the shower rotate the on off control...

Page 20: ...ssioned setting then ensure the strainers are clean and that the isolating valves are fully open Test the non return valves as described below If these tests do not highlight the reason for the temper...

Page 21: ...f the hot supply and ensure the cold supply is open Be prepared for leakage of trapped water in the pipe and remove the strainer basket on the hot side Evidence of continuing leakage from the strainer...

Page 22: ...Spray arm chrome 22009380 gold 22009390 7 Sprayhead chrome 22009340 gold 22009330 8 Mounting bracket 7012435 9 Flat bracket 7012436 Bracket assembly 83306290 comprising 8 9 10 Utilities pack 7102523 c...

Page 23: ...sioning details Hot water temp C Pressure Bar Equip used Cold water temp C Pressure Bar Equip used Max temp setting C C W fail C max Replacement dates O ring seals recommended every 3 years Thermostat...

Page 24: ...specification 1 4 1 Clean refer to maintenance section 1 5 1 Replace refer to maintenance section 2 1 1 Turn temperature control anti clockwise 2 2 1 Turn temperature control anti clockwise 2 3 1 Ens...

Page 25: ...23 DC7000 ANTIQUE...

Page 26: ...DC7000 ANTIQUE 24...

Page 27: ......

Page 28: ...rma invoice by cheque or money order 2 By telephone quoting credit card MasterCard or Visa details 3 By website order www tritonshowers co uk Triton Plc Shepperton Park Caldwell Road Nuneaton Warwicks...

Reviews: