DC7000 ANTIQUE
22
Any maintenance or repair to the shower must be carried out by a suitably qualified person.
1.1
Not enough cold water
flowing through shower.
1.2
Increase in the ambient cold
water temperature.
1.3
High volume of cold water
being drawn off elsewhere.
1.4
Dirty filters.
1.5
Internal parts failure
2.1
Not enough hot water
flowing through the shower.
2.2
Decrease in the ambient
cold water temperature.
2.3
Insufficient hot water
supplies from the heating
appliance.
2.4
Hot water supply blocked or
restricted.
2.5
Dirty filters.
2.6
Internal parts failure
3.1
Water supplies cut off.
3.2
Shower unit blocked.
3.3
Blockage in pipework.
3.4
Sprayhead blocked.
3.5
Reduced flow rate when
other outlets in use.
4.1
Debris damage to on/off
washer.
4.2
On/off washer worn.
1.1.1
Turn the temperature control clockwise.
1.2.1
Turn the temperature control clockwise.
1.3.1
Reduce the simultaneous demand from the
supply – ensure supply pressures are within
specification.
1.4.1
Clean – refer to maintenance section.
1.5.1
Replace – refer to maintenance section.
2.1.1
Turn temperature control anti-clockwise.
2.2.1
Turn temperature control anti-clockwise.
2.3.1
Ensure hot water appliance is set to deliver
correct hot water output temperature.
2.3.2
Combi boiler mutipoint installations check
flow limiter fitted.
2.4.1
Turn shower off and consult a competent
plumber or contact Triton Customer Service.
2.5.1
Clean – refer to maintenance section.
2.6.1
Replace – refer to maintenance section.
3.1.1
Check water elsewhere in property and if
necessary contact local water company.
3.2.1
Inspect filters – refer to maintenance
section. Clean if necessary.
3.3.1
Turn the shower off and consult a suitably
competent plumber.
3.4.1
Clean sprayhead.
3.5.1
Reduce the simultaneous demand at other
outlets.
3.5.2
Ensure service valves are fully open.
4.1.1
Replace washer – refer to maintenance
section.
4.2.1
Replace washer – refer to maintenance
section.
1
Water too
hot.
2
Water too
cold
3
Water does
not flow or
shower pattern
collapses when
another outlet
is turned on.
4
Shower will
not shut off
FAULT FINDING
Symptom
Cause
Action/cure