d) Valve installation in a panel or cubicle
To use the wall mounting bracket supplied with a
shower cubicle or a laminated panel, wooden
blocks are required to increase the depth of the
bracket. These blocks need to increase the depth
of the bracket to between 70.5 mm and 76.5 mm
from the finished surface (fig.15).
Decide on the shower position and determine
whether the hot and cold water supplies will enter
the shower from the top (falling) or bottom
(rising) or rear.
Mark the route of the incoming and outgoing
pipework. Only the two holes for the control
knobs require to be cut out of the panel or
cubicle. Use the supplied template as a guide
(fig.16).
After cutting the two holes, fit the valve to the
mounting bracket and secure using the four
screws provided.
Offer the valve and mounting bracket up to the
back of the panel ensuring the thermostatic and
on/off assemblies are protruding and centralised
through the apertures. Mark the four inner tapped
holes (fig.17). Remove the valve and bracket and
drill the panel and wooden blocks. Route the
pipework to valve position.
Flush out the pipework in accordance with
Water Regulation Byelaws .
Fit the mounting bracket together with the valve
to the panel and secure using the bolts and
washers provided.
Proceed to ‘connecting supply pipes’ section.
33 mm dia
Temperature
43 mm dia
99 mm
centres
Panel
surface
70.5 to 76.5 mm
Blocks
Fig.15
Fig.16