Outline of bath,

shower tray

or cubicle

Cold water supply

from cistern

(top, bottom or back)

Shower can
be mounted

either side of

the riser rail

Ceiling

Height of

sprayhead

and shower

to suit user’s

requirement

Shower unit

must not

be within

an area
1 metre

from base

Fig.5  

Diagrammatic view (not to scale)

SITING OF THE SHOWER

IMPORTANT:

If installing onto a tiled wall

always mount the unit on the surface of the
tiles. NEVER tile up to the unit.

Refer to 

fig.5

for correct siting of the shower.

This product is splashproof rated and is
approved for use in shower cubicles and over
baths. However, do not install the unit in a
position where the sprayhead will consistently
direct water over it.

The shower unit MUST be positioned vertically.

Allow enough room between the ceiling and
the shower to access the cover top screws.

Pressure relief safety device

A pressure relief device (PRD) is designed into
the shower unit which complies with European
standards. The PRD provides a level of
appliance protection should an excessive build
up of pressure occur within the shower.

DO NOT operate the shower with a damaged
or kinked shower hose, or a blocked sprayhead
which can cause the PRD to operate.

When commissioning, the sprayhead must be
removed from the flexible hose. Failure to
follow this procedure may also result in causing
the PRD to operate.

Make sure the shower is positioned over a bath
or shower tray because if the PRD operates, then
water will eject from the bottom of the unit.

Should this happen, turn off the electricity and
water supplies to the shower at the isolating
switch and stopvalve. Contact Customer Service
for advice on replacing the PRD.

The PRD is situated behind the outlet pipe

(fig.6)

. To access the PRD, FIRST SWITCH OFF

THE ELECTRICITY SUPPLY, unscrew the hose
then remove the cover. Remove the two screws
holding the outlet pipe to the base of the can.
Carefully pull away from the can and then
unscrew the two screws holding the PRD to the
outlet pipe.

CAUTION:

DO NOT attempt to replace the

PRD unless competent to do so.

Note:

Before replacing the cover, it is strongly

advised to prime the unit (see 

‘commissioning’

).

Two PRD
screws

PRD

Outlet pipe

Two outlet
pipe screws

Fig.6

WARNING!

The shower must not be positioned

where it will be subjected to

freezing conditions.

Summary of Contents for ASPIRANTE Series

Page 1: ...INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180445D May 2005 Aspirante pumped electric shower Installation and operating instructions...

Page 2: ...hose and sprayhead 15 Operating the shower 16 17 Operating functions 17 18 Adjusting the sprayhead 18 Cleaning 19 Instructions for installers and service engineers only 20 Spare parts 21 22 Fault fin...

Page 3: ...electrical connections 3 ELECTRICAL 3 1 The installation must comply with BS 7671 Requirements for electrical installations IEE wiring regulations Building Regulations or any particular regulations a...

Page 4: ...e with European Community Directives CE ADVICE TO USERS The following points will help you understand how the shower operates a The electric heating elements operate at a constant rate at your chosen...

Page 5: ...l block 9 Can and element assembly 10 Area for bottom and back pipe cable entry 11 Pressure switch 12 Temperature valve 13 Solenoid valve 14 Earth connection 15 Inlet pipe 16 Filter 17 Thermal cut out...

Page 6: ...switch off the whole installation at the consumer unit 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main spur socket outlet lighting circ...

Page 7: ...ated in any rooms other than bathrooms all socket outlets in those rooms must be protected by a 30mA RCD 9 To obtain full advantage of the power provided by the shower use the shortest cable route pos...

Page 8: ...a lower level Note The supply pipe from the cistern should be on the opposite side to the float operated valve to prevent air being drawn into the pipe when the cistern is filling If it is intended t...

Page 9: ...up of pressure occur within the shower DO NOT operate the shower with a damaged or kinked shower hose or a blocked sprayhead which can cause the PRD to operate When commissioning the sprayhead must be...

Page 10: ...ing will be partially behind the surface of the wall fig 10 This area must be left clear when plastering over the pipework to make the nut accessible for future adjustments Note Make sure the hole in...

Page 11: ...he plumbing connections have been completed Note A temporary factory fitted locking screw is fitted to the power selector spindle fig 16 This is to make sure the spindle is in the Cold position while...

Page 12: ...water supply to the inlet of the shower flush out the pipework to remove all swarf and system debris This can be achieved by connecting a hose to the pipework and turning on the water supply long eno...

Page 13: ...cable overheating Note The supply cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable must be secured either by routing thr...

Page 14: ...16 it can be removed when the commissioning procedure has been completed Make sure the water supply is still turned on to the shower Open the bleed screw on the pump unit fig 17 by rotating one revolu...

Page 15: ...r indicator will light and the pump starts to operate It will take about thirty seconds for a smooth flow of water to be obtained while air and any debris is being flushed from the shower When a smoot...

Page 16: ...appropriate masonry drill but if wall is plasterboard or a soft building block you must use suitable wallplugs and a suitable drill bit With the saddle spacer and lever parts to hand screw the saddle...

Page 17: ...y in the soap dish fig 31 so that the dish is held at the required height on the rail FITTING THE HOSE AND SPRAYHEAD Feed the flexible hose through the soap dish opening fig 32 so that the dish acts a...

Page 18: ...low setting for extra economy during warmer months Temperature adjustment at this setting is via the temperature control Single red symbol is the medium setting for economy during warmer months and a...

Page 19: ...wering Special consideration should be given to young children and the less able bodied OPERATING FUNCTIONS Power on indicator fig 36 The power neon will light when the Start Stop button is pressed Th...

Page 20: ...unit the device will disconnect the heating elements It will require a visit from a qualified engineer to determine the nature of the fault and replace the safety device once the unit has been repair...

Page 21: ...cartridge firmly and continue to twist anti clockwise Having loosened the sprayplate it can be unscrewed and removed completely Clean the sprayplate with a suitable brush or preferably leave it to soa...

Page 22: ...rrying out repairs or service to other areas of the shower unit Unscrew the filter fig 40 by turning anti clockwise Remove the unit complete with the filter and wash under running water Make sure all...

Page 23: ...sembly dual rated 240V 230V 9 5kW 8 7kW 84500790 5 Selector switch microswitch wire assy 82500250 6 Flow valve assembly 82100310 7 Inlet pipe assembly 83306460 5 1 2 6 4 3 9 8 7 10 Ref Description Par...

Page 24: ...ode sprayhead chrome 22011130 12 Brackets pair chrome 83306170 13 Riser rail plated chrome 7042412 14 Sprayhead holder chrome 83306200 15 Soap dish clear 22008970 16 Flexible hose chrome effect 281000...

Page 25: ...ian 1 2 1 Remove the cover and make sure the plug and socket are firmly connected 1 3 1 Have solenoid checked by a competent electrician or contact Customer Service 1 4 1 If the power neon is lit when...

Page 26: ...t removed while commissioning 5 1 1 See 1 1 1 and 1 1 2 5 2 1 Switch off immediately Have solenoid checked by a competent electrician or contact Customer Service 5 3 1 See 1 5 1 6 1 1 Check the filter...

Page 27: ...25 Aspirante pumped electric UKAS QUALITY MANAGEMENT 003...

Page 28: ...roup Holdings Limited Earthridge Customer Service Republic of Ireland 01 628 6711 01 628 6845 Service Policy In the event of a complaint occurring thefollowing procedure should be followed 1 Telephone...

Reviews: