Triton ASPIRANTE Series Installation And Operating Instructions Manual Download Page 4

Aspirante pumped electric

INTRODUCTION

This book contains all the necessary fitting and
operating instructions for your Aspirante
pumped electric shower. Take time to read this
book thoroughly and familiarise yourself with all
instructions before commencing installation.
Please keep it for future reference.

The shower installation must be carried out in
the sequence of this instruction book.

Do not attempt any electrical or plumbing work
necessary to install this product unless you have
good practical experience and adequate
understanding of the IEE regulations and water
regulations

Care taken during the installation will give a
long, trouble-free life from your shower.

SPECIFICATIONS

Electrical

Nominal power rating at 230V

8.7kW – (40A MCB rating)

Nominal power rating at 240V

9.5kW – (40A MCB rating)

Pump motor rating 120 Watt 

single phase.

Water

Inlet connection – 15mm diameter.
Outlet connection – ½” BSP male thread.

Entry Points

Water – top, bottom or back.
Cable – top, bottom or back.

Materials

Backplate, cover, controls, sprayhead – ABS.
Elements – Minerally insulated corrosion
resistant metal sheathing.

Dimensions

Height 

261 mm

Width 

330 mm

Depth 

104 mm

Standards and Approvals

Splashproof rating IPX4.

Complies with the requirements of current
British and European safety standards for
household and similar electrical appliances.

Complies with requirements of the British
Electrotechnical Approvals Board (BEAB).

Meets with Compliance with European
Community Directives (CE).

ADVICE TO USERS

The following points will help you understand
how the shower operates:

a.

The electric heating elements operate at a
constant rate at your chosen power setting.
It is the rate of the water passing through
the heater unit which determines the shower
temperature at any given setting. (The
slower the flow the hotter the water
becomes, and the faster the flow the cooler
the water).

b.

During the winter the cold water supply will
be cooler than in the summer months.
Therefore, the temperature of the water will
vary from season to season on any one
setting of the temperature control, e.g. if
you have chosen 'Medium' power for your
preferred shower temperature in the
summer, you may have to increase that to
'Full' power during the winter months.

c.

If for any reason there is a sudden rise in
water temperature, the Aspirante pumped
electric shower has thermal cut-out devices
built-in (see items 3 and 4 under 

‘Fault

Finding’

).

d.

Switch off immediately at the isolating
switch if water ceases to flow. Press the
Start/Stop button and contact Triton
Customer Service for advice.

If ever the water becomes too hot and you
cannot obtain cooler water, first check that the
sprayplate in the sprayhead is not blocked.

DO NOT place items such as soap or shampoo
bottles on top of the unit. Liquid could seep
through the joint between the cover and
backplate, and possibly damage the sealing
rubber.

Replacement parts can be ordered from Customer
Service. See 

'spare parts'

for details and part numbers.

Due to continuous improvement and updating,
specification may be altered without prior notice.

2

Summary of Contents for ASPIRANTE Series

Page 1: ...INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180445D May 2005 Aspirante pumped electric shower Installation and operating instructions...

Page 2: ...hose and sprayhead 15 Operating the shower 16 17 Operating functions 17 18 Adjusting the sprayhead 18 Cleaning 19 Instructions for installers and service engineers only 20 Spare parts 21 22 Fault fin...

Page 3: ...electrical connections 3 ELECTRICAL 3 1 The installation must comply with BS 7671 Requirements for electrical installations IEE wiring regulations Building Regulations or any particular regulations a...

Page 4: ...e with European Community Directives CE ADVICE TO USERS The following points will help you understand how the shower operates a The electric heating elements operate at a constant rate at your chosen...

Page 5: ...l block 9 Can and element assembly 10 Area for bottom and back pipe cable entry 11 Pressure switch 12 Temperature valve 13 Solenoid valve 14 Earth connection 15 Inlet pipe 16 Filter 17 Thermal cut out...

Page 6: ...switch off the whole installation at the consumer unit 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main spur socket outlet lighting circ...

Page 7: ...ated in any rooms other than bathrooms all socket outlets in those rooms must be protected by a 30mA RCD 9 To obtain full advantage of the power provided by the shower use the shortest cable route pos...

Page 8: ...a lower level Note The supply pipe from the cistern should be on the opposite side to the float operated valve to prevent air being drawn into the pipe when the cistern is filling If it is intended t...

Page 9: ...up of pressure occur within the shower DO NOT operate the shower with a damaged or kinked shower hose or a blocked sprayhead which can cause the PRD to operate When commissioning the sprayhead must be...

Page 10: ...ing will be partially behind the surface of the wall fig 10 This area must be left clear when plastering over the pipework to make the nut accessible for future adjustments Note Make sure the hole in...

Page 11: ...he plumbing connections have been completed Note A temporary factory fitted locking screw is fitted to the power selector spindle fig 16 This is to make sure the spindle is in the Cold position while...

Page 12: ...water supply to the inlet of the shower flush out the pipework to remove all swarf and system debris This can be achieved by connecting a hose to the pipework and turning on the water supply long eno...

Page 13: ...cable overheating Note The supply cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable must be secured either by routing thr...

Page 14: ...16 it can be removed when the commissioning procedure has been completed Make sure the water supply is still turned on to the shower Open the bleed screw on the pump unit fig 17 by rotating one revolu...

Page 15: ...r indicator will light and the pump starts to operate It will take about thirty seconds for a smooth flow of water to be obtained while air and any debris is being flushed from the shower When a smoot...

Page 16: ...appropriate masonry drill but if wall is plasterboard or a soft building block you must use suitable wallplugs and a suitable drill bit With the saddle spacer and lever parts to hand screw the saddle...

Page 17: ...y in the soap dish fig 31 so that the dish is held at the required height on the rail FITTING THE HOSE AND SPRAYHEAD Feed the flexible hose through the soap dish opening fig 32 so that the dish acts a...

Page 18: ...low setting for extra economy during warmer months Temperature adjustment at this setting is via the temperature control Single red symbol is the medium setting for economy during warmer months and a...

Page 19: ...wering Special consideration should be given to young children and the less able bodied OPERATING FUNCTIONS Power on indicator fig 36 The power neon will light when the Start Stop button is pressed Th...

Page 20: ...unit the device will disconnect the heating elements It will require a visit from a qualified engineer to determine the nature of the fault and replace the safety device once the unit has been repair...

Page 21: ...cartridge firmly and continue to twist anti clockwise Having loosened the sprayplate it can be unscrewed and removed completely Clean the sprayplate with a suitable brush or preferably leave it to soa...

Page 22: ...rrying out repairs or service to other areas of the shower unit Unscrew the filter fig 40 by turning anti clockwise Remove the unit complete with the filter and wash under running water Make sure all...

Page 23: ...sembly dual rated 240V 230V 9 5kW 8 7kW 84500790 5 Selector switch microswitch wire assy 82500250 6 Flow valve assembly 82100310 7 Inlet pipe assembly 83306460 5 1 2 6 4 3 9 8 7 10 Ref Description Par...

Page 24: ...ode sprayhead chrome 22011130 12 Brackets pair chrome 83306170 13 Riser rail plated chrome 7042412 14 Sprayhead holder chrome 83306200 15 Soap dish clear 22008970 16 Flexible hose chrome effect 281000...

Page 25: ...ian 1 2 1 Remove the cover and make sure the plug and socket are firmly connected 1 3 1 Have solenoid checked by a competent electrician or contact Customer Service 1 4 1 If the power neon is lit when...

Page 26: ...t removed while commissioning 5 1 1 See 1 1 1 and 1 1 2 5 2 1 Switch off immediately Have solenoid checked by a competent electrician or contact Customer Service 5 3 1 See 1 5 1 6 1 1 Check the filter...

Page 27: ...25 Aspirante pumped electric UKAS QUALITY MANAGEMENT 003...

Page 28: ...roup Holdings Limited Earthridge Customer Service Republic of Ireland 01 628 6711 01 628 6845 Service Policy In the event of a complaint occurring thefollowing procedure should be followed 1 Telephone...

Reviews: