INSTRUCTIONS FOR INSTALLERS AND SERVICE ENGINEERS ONLY
20
Aspirante pumped electric
CLEANING THE FILTER
It is recommended that the filter is periodically
cleaned in order to maintain the performance
of the shower. It is essential that this operation
is carried out by a competent person.
SWITCH OFF THE ELECTRICITY SUPPLY AT THE
MAINS.
Remove the cover and disconnect the plug.
Note:
Should debris be trapped on the shut off
seat inside the valve, water will continue to flow
out as the filter is removed. Before removing
the filter turn off the supplies at the service
valve .
DO NOT rely on the filter shut off valve when
carrying out repairs or service to other areas of
the shower unit.
Unscrew the filter
(fig.40)
by turning anti-
clockwise. Remove the unit complete with the
filter and wash under running water. Make sure
all debris is removed.
Replace by pushing the unit back into its
housing until the threads engage and then turn
fully clockwise until tight. DO NOT
OVERTIGHTEN.
Before replacing the cover, it is strongly advised
to prime the unit by opening the bleed screw
until water drains from it.
Close the bleed screw and connect the plug to
the cover. Replace the cover and secure with
the fixing screws.
Switch on the electric supply and start the
shower on the COLD SETTING ONLY and with
the temperature control rotated fully anti-
clockwise.
When a smooth flow of water is obtained, the
shower can then be used in the normal manner.
Fig.40