Maintenance
SeaKing & SeaPrince Imaging Sonars
0374-SOM-00001, Issue: 08
38
© Tritech International Ltd.
The highlighted areas on the image above are the critical sealing areas that should have no
signs of corrosion. If corrosion is present within either of these areas, please contact
Tritech
International Ltd
to arrange for immediate servicing of your Super SeaPrince unit.
6.4.2. Reassembly of the Super SeaPrince unit
Important
The steps outlined here will expose sensitive electronic equipment and so
appropriate steps should be taken to prevent any static discharge occurring
which may harm the equipment.
Caution
Servicing of the SeaKing unit should only be carried out by competent personnel
in a dry, clean environment with full ESD precautions.
Service tools required
• Clean absorbent wipes
• Silicon grease MS-111 lubricant (or equivalent)
• A M3 Allen Key or Hex driver
Procedure
1. Carefully clean all parts and check for damage.
2. Inspect o-ring seals and replace if necessary.
3. Using the M3 Allen key, fit the MAIN and AUX (if applicable) waterblocks. Each of the
waterblock screws should be tightened, in turn, by a quarter turn until the waterblock is
flush and level to the connector endcap
4. Using the M3 Allen Key, fit the Pressurised blanking cap (if applicable) either directly onto
the AUX port, or on the AUX waterblock if it not to be used.
5. Visually inspect the unit to ensure that all surfaces have mated correctly