9

Condition

LCD Display Message

Overload Shutdown

ON BYPASS
OVERLOAD 150%
SHUTDOWN...
VERSION: XXXXXXX

UPS Output Short Circuit

ON BYPASS
SHORT CIRCUIT!
SHUTDOWN...
VERSION: XXXXXXX

Overtemperature

ON BYPASS
HIGH TEMP!
SHUTDOWN...
VERSION: XXXXXXX

DC BUS Overvoltage

ON BYPASS
DC BUS O.V.P.!
SHUTDOWN...
VERSION: XXXXXXX

DC BUS Failure

ON BYPASS
DC BUS FAIL!
SHUTDOWN...
VERSION: XXXXXXX

Condition

LCD Display Message

R/S/T Inverter Output Failure

ON BYPASS
R OUTPUT FAIL!
SHUTDOWN...
VERSION: XXXXXXX

Low Battery

BYPS OFF NO O/P
LOW BATTERY!
SHUTDOWN...
VERSION: XXXXXXX

Remote Shutdown

BYPS OFF NO O/P
REMOTE SHUTDOWN
SHUTDOWN...
VERSION: XXXXXXX

Emergency Stop

BYPS OFF NO O/P
EMERGENCY STOP!
SHUTDOWN...
VERSION: XXXXXXX

When the inverter is ON, the LCD Display may show any one of the following warnings:

Condition

LCD Display Message

UPS Output Overload

OVERLOAD 110%

UPS Charger Failure

CHARGER FAILURE

Abnormal Input Frequency

FREQUENCY ERROR

Abnormal Input Phase

PHASE ABNORMAL!

Battery is Depleting*

ON BATTERY

Battery Charge is Nearly Depleted*

BATTERY LOW.

* During a prolonged blackout, users should save files and shut down connected equipment.  The “BATTERY 
LOW” message indicates the UPS's batteries are nearly out of power and UPS shutdown is imminent

Your UPS will shut down and the LCD will display a message if it detects one of the following conditions. 

Note:

 

For all conditions, the “Input,” 

“Output” and “Bypass” LEDs will be illuminated.

Warning: Failure to follow this procedure could damage the unit and void its warranty.
Warning: When installing the unit, verify that any maintenance bypass panel used is configured correctly before applying power to the unit.

Turn this switch to “BYPASS” before performing any maintenance on the UPS with the connected load supported. Connected equipment will receive 
filtered AC mains power, but will not receive battery power in the event of a blackout.

SWITCHING UPS TO “BYPASS” MODE

Press the “OFF” button. 

• 

Turn the “Manual Bypass” Switch clockwise from NORMAL to 

• 

BYPASS.
Turn the Main Input Switch Circuit Breaker OFF.

• 

SWITCHING UPS TO “NORMAL” MODE

Turn the Main Input Switch Circuit Breaker ON.

• 

Turn the “Manual Bypass” Switch counterclockwise from BYPASS 

• 

back to NORMAL.
Press the “ON” button.

• 

5.2 Inverter On Warnings

5.3 Operation Under Shutdown

5.4 Operation Of Manual Bypass Switch

5. Operation (Special Conditions) 

(continued)

Summary of Contents for SmartOnline 120/208V

Page 1: ...Operation Of Manual Bypass Switch 9 6 Communications 10 6 1 RS 232 Interface 10 6 2 AS 400 Interface 10 6 3 Dry Contact Interface 10 6 4 Remote Emergency Power Off EPO 11 7 Adding or Replacing Intern...

Page 2: ...where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not use this...

Page 3: ...l illuminate constantly to indicate the UPS s AC DC converter is activated BATTERY LED 9 This red light will flash when the UPS is discharging the battery to provide connected equipment with AC power...

Page 4: ...s Internal Battery Pack Connectors Red Black 3 Connect the individual internal battery packs to the overall battery system Internal Battery Pack Jumper Cables White Blue 4 Connect the internal battery...

Page 5: ...ort 7 This female DB9 port sends contact closure signals to indicate line fail and low battery status See section 6 Communications Accessory Slot 8 Remove the small cover panel and use optional access...

Page 6: ...h a torque of not less than 35 inch lbs 3 9 NM Keep ground wire connected at all times after installation Warning When installing the unit verify that any maintenance bypass panel used is configured c...

Page 7: ...Turn the AC Main Input Switch and Bypass Input Switch Circuit Breakers ON If your AC input is providing power normally within your selected range your connected load will energize in Bypass However t...

Page 8: ...SELECT Button Press SELECT Button Press SELECT Button Press SELECT Button Press SELECT Button Press SELECT Button Press SELECT Button While in Bypass Mode the UPS monitors the input voltage which on B...

Page 9: ...should save files and shut down connected equipment The BATTERY LOW message indicates the UPS s batteries are nearly out of power and UPS shutdown is imminent Your UPS will shut down and the LCD will...

Page 10: ...to an IBM AS 400 computer via an AS 400 cable The port uses AS 400 communications to report UPS status It can be used to allow an AS 400 to automatically save open files and shut down its operating sy...

Page 11: ...plastic sleeve covering the battery strings The sleeve is designed to prevent accidental contact with the terminals on the individual batteries Contact with the terminals will create a potential for s...

Page 12: ...wiring diagram prior to adding or replacing batteries The battery module can accept up to four battery packs each pack consisting of two strings The diagram shows all four battery packs connected for...

Page 13: ...nect the RED and BLACK cables attached to each internal battery pack 3 3 Remove the battery cartridge fuses from each fuse block Save the fuses 4 4 Disconnect the BLUE and WHITE jumper cables attached...

Page 14: ...nd position the cable to allow adequate room to add the battery strings 7B 7 7 Slide the battery string with the BLACK cable next to it on the left in the empty slot as shown Make sure that the string...

Page 15: ...connector connect the voltmeter s RED probe to the battery pack s RED connector To get a proper reading make sure the voltmeter s probes touch the metal contacts inside the battery pack s connectors T...

Page 16: ...y Void where prohibited Some restrictions apply See website for details Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification your Tri...

Page 17: ...odel SU20K3 3XR5 Input Input Voltage 120 208V AC 3 4 Wire plus ground wye Input Frequency 60 Hz 3 Hz Voltage Correction Range 88 144 166 250V AC Input Current Per Phase On Line 60A Inrush Current 300A...

Page 18: ...ltage 120 208V AC 3 4 Wire plus ground wye Input Frequency 60 Hz 3 Hz Voltage Correction Range 88 144 166 250V AC Input Current Per Phase On Line 90A Inrush Current 300A Power Factor Full Load 0 95 Ef...

Reviews: