background image

 

 
User Manual  
Mobile Power System

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

 

Version 1.0 
© 2012 Jansen Medicars 

 

 

Summary of Contents for Mobile Power System

Page 1: ...User Manual Mobile Power System Version 1 0 2012 Jansen Medicars ...

Page 2: ...d Niets uit deze uitgave mag worden gedupliceerd zonder schriftelijke toestemming van Jansen Medicars No rights can be derived from this publication Nothing may be duplicated from this publication without written permission from Jansen Medicars Aucun droit ne peut être tiré de cette publication Toute reproduction même partielle est interdite sans autorisation écrite de Jansen Medicars ...

Page 3: ...agina 1 Table of content 1 INTRODUCTION 2 1 1 BOOKMARK 2 2 GENERAL SAFETY RULES 3 3 INSTRUCTIONS FOR USE 6 4 SYSTEM SET UP AND SPECIFICATIONS 8 4 1 BLOCK DIAGRAM 8 4 2 BATTERY TIME 9 4 3 SPECIFICATIES 10 5 INSPECTION AND MAINTENANCE 11 ...

Page 4: ...or the first time it has to be charged for at least 16 hours See also Chapter 3 1 1 Bookmark Important Read these directions for use in their entirety before you use this system Take the directions for safety chapter 2 especially into consideration Do not work on the system if you do not possess the necessary knowledge or if you are not authorised to do so Jansen Medicars cannot be held responsibl...

Page 5: ...before replacing them Replace only by fuses of the same type and current Make sure the batteries are in optimum condition at all times by means of charging them when the system is not in use Do not connect more than 4 medical devices to the system in order to keep the earth leakage current on the output below 5mA The supplied 5 meter long power cord is rated for medical use Always connect power pl...

Page 6: ... NOT OPERATE POWER SYSTEM IF WET DO NOT ALLOW THE SYSTEM OR POWER CORD TO OVERHEAT DO NOT drive drag or place objects over the power cord Do not stand or walk on the power cord EQUIPMENT not suitable for use in the presence of a FLAMMABLE ANESTHETIC MIXTURE WITH AIR or WITH OXYGEN OR NITROUS OXIDE Cleaning Before cleaning always switch off the system and remove the power plug of the mains cable fr...

Page 7: ...u notice irregularities have them checked by a qualified person Technical maintenance must always be carried out by qualified personnel The cart must be checked at least once a year by technical personnel Important points are check for wear and tear check screws welding and battery condition Also check if the system works properly and check the earth leakage current of both input and output ...

Page 8: ...hrough to outputs Yellow 230VAC output voltage is derived from the battery Battery condition indicator Output 4x IEC320 each equipped with a equipotentiality connection Mounting system for Crozz one cart Fuses 2x 5AT 6 3x32mm Using the On Off switch the 230VAC to the output can be switched on and off The output voltage is provided by either the internal inverter or via the power cord when connecte...

Page 9: ...itch of within a short period of time In this situation it is recommend to connect the system to the mains power so that the batteries are charged and the output will not be switched off The reading on the battery condition indicator will remain unchanged during the entire charging process Only when the battery is completely full the rightmost LED lights up again On the rear side of the system 4 o...

Page 10: ...eakage current the total leakage current at the input remains less than 500µA The output of the system features 4 outputs for the connection to medical grade equipment The maximum earth leakage current for each of the connected electrical systems must be less than 500µA Because the internal earth leakage current of the internal inverter is less tan 3mA the total leakage current on the output remai...

Page 11: ...s an indication of the battery time h as a function of power demand in VA Time hours Power consumption VA Recharging the batteries is provided by an internal battery charger The charging time for an empty battery pack lasts up to 16 hours 0 5 10 15 20 25 0 100 200 300 400 500 600 ...

Page 12: ...0 ms Electrical inpuy Voltage 230 VAC 50Hz Earth leakage current 500 µA Battery package Type Valve Regulated Lead Acid Voltage 24 V 2x12V battery Capacity 50 Ah Inverter Output voltage 230VAC 2 Alternating current True sine wave THD 5 600VA Maximum load 600 VA Output frequency 50 Hz 0 05 Max efficiency 93 Permitted cos φ 0 2 1 Battery Charger Type 3 stage charger Charging currunt 5 A 10 van de bat...

Page 13: ... Replace when necessary 4 Check the condition of the battery If the battery time is too short for the application they should be replaced Always replace batteries by the same type 5 Verification of correct operation a Check for correct switching between mains voltage and voltage generated by the inverter b Check the output voltage c Checking the LED indicators and the battery discharge indicator 6...

Page 14: ......

Page 15: ......

Page 16: ...Jansen Medicars modulaire cart concept The optimal solution for every application Typical product application Wireless Monitor Cart ...

Reviews: