TRIO TeST & MeaSUReMeNT
27
Copyright 2015 all rights reserved
Where it is not practical to use the stainless steel cloak to Test
Double Insulated Appliances, the following may be used:
• Probe Test or
The
Pro Logger II
has this Probe Test mode, available on all
testers with Firmware Version V4.46 and above.
If purchased with a Cloak the
SafeTcheck
uses the unique
feature
in conjunction with the Stainless
Steel Cloak to perform an Insulation Resistance (IR) test on
Double Insulated Appliances.
ensures the
Device Under Test (DUT) is both correctly connected to the
SafeTcheck
(to provide a return path for leakage currents) and
its exposed surfaces are adequately covered to reduce the
chance of an erroneous test result.
During a Probe Test the
feature is disabled.
This gives the operator the ability to use the probe, the cloak or
a combination of both to test Double Insulated Appliances. The
test also provides adequate time to move the probe to several
points on the DUT’s surface before the test is complete.
SafeTcheck PRO LOggeR II
USING PROBE IN PROBE MODE
WaRNINg
If the Earth Resistance threshold
is set to 0.2 Ohms, only the
Insulation Resistance Test and
the Earth Only Test using the
Insulation Resistance socket will
give accurate results. Do not use
the Run Test socket with this
threshold.
utilities Menu
(F2 key)
WaRNINg
DO NOT uSE ThE CLOAK for
live tests
. The cloak may become
entangled in moving parts or
have resistance too high to be
effective. Only use the return lead
in conjunction with the Probe for
live run tests.