Overview
When fitted, the Battery Power Option will power the
SafeTcheck
for far in excess of 360 Tests (more than one
day's testing). This option will remove the need for mains
power and makes the
SafeTcheck
truly portable.
Users of the Battery Power should note:
1. Insulation and earth testing only are available in Battery
mode
2. To enter Battery mode press “Start” until the
SafeTcheck
beeps (battery symbol in the bottom left corner of display
will appear in this mode)
3. In Battery mode, if no key is pressed after 5 minutes, the
SafeTcheck
will automatically shut down. Holding “reset”
down will also shut it down
4. The
SafeTcheck
may be switched from battery to mains
without losing power (the battery will not charge in this
mode – see Battery Charge Mode)
5. Failing to follow these instructions will reduce battery life
and void the battery’s warranty
Operation
For a new
SafeTcheck
– ensure the battery/batteries are initially
fully charged:
1. Power the
SafeTcheck
from mains power
2. Set the
SafeTcheck
into Charge mode (see below)
3. Wait for “Charge Complete” prompt to appear and then
press “Start” to acknowledge the changed condition.
4. Turn the Pro Logger off by disconnecting the mains power
battery Charge Mode
(following these steps will extend the
life of the battery):
1. Power the
SafeTcheck
from mains power (If already on,
switch off and back on again)
2. The prompt “select test” needs to be displayed (If in
database mode, press reset unil “select test” is displayed).
The Battery will now be charging
3. Wait for the “Charge complete” prompt to appear
4. Press “Start” to acknowledge the charged condition
5. When fully charged the
SafeTcheck
may be stored. It is
also ready for appliance testing
NOTeS:
1. The battery will not charge while the
SafeTcheck
is in
any Test mode
2. A low battery condition will display a screen message
“Low battery reconnect to mains”
3. Storing the
SafeTcheck
with flat or partially charged
batteries will decrease the life of the batteries
4. Recharge at least every 6 months, more often if
possible