![Trio SafeTcheck Nanto Operator'S Manual Download Page 16](http://html1.mh-extra.com/html/trio/safetcheck-nanto/safetcheck-nanto_operators-manual_1163529016.webp)
SafeTcheck OPeRaTOR'S MaNUaL
16
Operating Instructions
The
SafeTcheck
is capable of testing many electrical
appliances with unusual characteristics. The Other Appliance
menu is used to select the test suitable for any of these
appliances. The user may scroll though the list by using the
F1 and F2 keys.
1 Appliances such as those fitted with surge protection
or MOVs (Metal Oxide Varistors) may be tested at 250V
(instead of 500V) by selecting one of the following:
• Class 1 250V
• Class 2 250V
2 Appliances requiring the mains voltage to be applied to
activate the On/Off switch, shall have their leakage current
checked by selecting one of the following:
• Class 1 Run Test
• Class 2 Run Test
(see also Run testing)
3 An earth continuity test may be conducted by selecting:
• Earth only test (see Safety Testing Earthed Appliances)
SELECT
OTHER
APPLIANCE
4 Appliances employing Mineral Insulated Metal Sheath
(MIMS) such as stoves and electric jugs may be tested
using a run test by selecting:
• MIMS Run Test
5 As for appliances in 1 above EPODs with surge protection
may be tested at 250V by selecting:
• EPOD 250V
6 RCDs rated at 10mA, 30mA either portable or fixed
may be tested by selecting one of the following:
• 10mA Portable RCD
• 30mA Portable RCD
• 10mA Fixed RCD
• 30mA Fixed RCD
7 Appliances employing a PIEZO starter such as the starter
on a portable gas stove may be tested by performing a:
• PIEZO Run Test