www.energyabsorption.com
Revision B June 2013
www.highwayguardrail.com
38
All rights in copyright reserved
10)
Assemble and Tension the Cartridge Support Cables
There are six Cartridge Support Cables. Pass the stud end of the cable through the
corresponding cartridge chain loop and attach as shown in Figure 36 using a die spring,
washer, and nuts.
To properly tension the Cartridge Support Cables, tighten the
fi
rst nut on one cable until
all slack is removed then tighten it until the tensioning springs have been compressed
to 32 mm [1 1/4"] in height. Lock this nut in place with the second “jam” nut. Repeat this
procedure with the other cables.
11)
Adjust the Height and Levelness of the System Frame
Verify that the System Frame is 305±25 mm [12”±1”] from the ground at the front and
rear of the system. It may be necessary to add shims to the Socket Hitches in order to
adjust the levelness of the Cartridge (See Figure 36a).
Figure 36a
Figure 36
± 2 mm [1 1/4" ± 1/16”]