Page 2-4
back onto the scale. Turn the scale on with the on/off switch located on the remote
keypad.
5. Remove the stainless steel top and disconnect all cables from the control module. Place
the scale base in the location provided (between ticket counters).
6. Center the frame in the opening. Adjust the leveling legs so that the scale base is in a
level position. Tighten the locknuts on the leveling feet.
7. Use the Scale Anchor Holes at each side of the lower frame (
see fig. 2-5
) to secure the
scale base in place with the eight (8) anchor bolts provided.
8. Attach the kick plates to the front and rear side of the lower frame. The kick plates attach
with Velcro so that they can be easily positioned and compensate for varying height and
level conditions.
9.
The scale base must be grounded
with the lead attached to the top frame. The center
screw on an electrical outlet or a metal conduit is usually suitable. Leave some slack in
the wire. Do not pull the wire tight because it can negatively affect weighing
performance.
2.4
Scale Base Installation (600-E Low Profile Style)
1. Remove the stainless steel platform cover by lifting it straight up. Remove the carton(s)
of electronics and verify that all components are present (
see table 2-1
).
2. Locate the four (4) Leveling Feet. Thread the leveling feet all the way into the threaded
load cell holes in all four (4) corners of the scale frame (
see fig. 2-6
).
Fig. 2-6:
Corner Detail
3. Before beginning installation into the counter it is recommended to perform an initial
check of the scale system. Set the scale base on the floor, level the scale and plug all
components into the control module. All the ports on the control module and cables are
clearly marked (
see
fig. 2-3
for System Block Diagram
). Place stainless steel platter
back onto the scale. Turn the scale on with the on/off switch located on the remote
keypad.
4. Remove the stainless steel top and disconnect all cables from the control module. Place