background image

Cardinal

Cardinal Scale Manufacturing Co.

®

DIGITAL HANGING SCALE

BATTERY OPERATED

HSDC SERIES

Operation Manual

PO BOX 151, WEBB CITY, MO 64870

PH 417-673-4631 • FAX  417-673-5001

Web site-http://www.cardinalscale.com

8551-M256-O1 Rev J
06/05

Printed in USA

Summary of Contents for HSDC series

Page 1: ... Manufacturing Co DIGITAL HANGING SCALE BATTERY OPERATED HSDC SERIES Operation Manual PO BOX 151 WEBB CITY MO 64870 PH 417 673 4631 FAX 417 673 5001 Web site http www cardinalscale com 8551 M256 O1 Rev J 06 05 Printed in USA ...

Page 2: ...2 ...

Page 3: ...attery requirements 6 each C size alkaline Weight 5 lb Ultimate safe overload 200 TABLE OF CONTENTS Introduction 1 Specifications 1 Battery Installation 2 Scale Operation 3 Tare Weight Entry 4 Display Codes 5 Calibration 6 Setup Review 10 Sealing 10 Do s And Don ts 10 In Case Of Difficulty 11 Serial Number_________________________ Date Of Purchase______________________ Purchased From______________...

Page 4: ...g scale This same procedure should also be followed when battery replacement becomes necessary Make certain that only C size alkaline batteries are used as replacements NOTE Exposure of batteries to high temperatures above 140 F will decrease their capacity resulting in shorter operation time Step 1 Using a screwdriver remove the two retaining screws from the back of the instrument Remove the batt...

Page 5: ...ations can begin it will be necessary to install batteries in the scale Refer to the battery installation section of this manual for additional information Hang the scale from a support that is strong enough to support the weight of the scale PLUS the weight of the material that is to be weighed Hang the load receiving element on the hook on the bottom of the scale and press the ON ZERO key Look a...

Page 6: ... the scale is in the net weight mode If it is off it indicates that the scale is in the gross weight mode LO BAT Illuminated to signal that the batteries should be replaced ZERO Illuminated to show that the scale weight is within 1 4 graduation of the center of zero TARE WEIGHT ENTRY The HSDC has an automatic tare feature that allows you to enter tare weight up to the three least significant digit...

Page 7: ...e capacity will result in a overload condition and display ot For example using the HSDC 20 from above with tare weight of 2 00 lb adding 19 00 lb to the platform will cause an overload condition This is because 2 00 lb tare weight plus 19 00 lb load weight equals 21 00 lb gross weight which exceeds the capacity of the scale DISPLAY CODES During operation of the HSDC hanging scale you may encounte...

Page 8: ...qualified scale technician should be consulted before any attempt at calibration is made NOTE This scale is provided with a means of attaching a seal to prevent access to the calibration switch Calibration Procedure Step 1 Remove the seals if present from the calibration cover plate then remove the two retaining screws and cover plate Step 2 Hang the scale from a suitable support and attach the lo...

Page 9: ...test weights and press the NET key The display will show then proceed to the next prompt ZERO TRACKING RANGE Press the NET key to show the current division setting Values of 0 through 9 and 0 5 are valid for the zero tracking range Press the ON ZERO key to step through and select 0 5 as the division value then press the NET key to save If a zero tracking range division of 0 through 9 is desired fi...

Page 10: ...2 samples per second Press the NET key to save AUTOMATIC SHUTOFF Press the NET key to show the current setting Then press the ON ZERO key to disable the feature or to select the number of minutes of inactivity before turning off the scale 0 disable 1 to 9 minutes of inactivity before shutoff Press the NET key to save it SLEEP MODE Press the NET key to show the current setting Then press the ON ZER...

Page 11: ... FLt UnS Sr ASh SLP Pbt 2 1 5000 1 0 5 no 1 y y y y y y y y 500 200 100 40 20 100kg 40kg 20kg no no no no no no no no 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 Calibration Switch Front of Instrument Underside of Scale CALIBRATION Cont Table 1 Setup Settings for HSDC Models trL YES is for Canadian use Skip if FLt 1 or 2 End of Calibration Section Go to Setup Review Fine Span ...

Page 12: ...le the indicator is on by pressing and holding the calibration switch and pressing the ON ZERO or NET key Calibration Switch ON ZERO increase Calibration Switch NET decrease Go to Sealing Instructions SEALING INSTRUCTIONS To attach the seals first make certain the two cover plate retaining screws are snug then thread the seal wires through the hole in the screw heads as shown in the calibration se...

Page 13: ...s dead A Batteries improperly installed make certain each of the six batteries is correctly installed No display B Batteries are discharged completely replace with fresh batteries 2 Incorrect weight A Scale not at zero prior to applying weight remove load and reset display to zero by pressing ON ZERO key B Scale is not calibrated Refer to Calibration Section of this manual C Scale in net mode Pres...

Page 14: ...2 ...

Page 15: ...2 ...

Page 16: ...U N A M E D S I G U N E D F A C T R E D I N U S A U N A M E D S I G U N E D F A C T R E D I N U S A ...

Reviews: