7
CALIBRATION, Cont.
DECIMAL POINT
Press the
NET
key to show the current setting. Then press the
ON/ZERO
key to
select the desired value:
0=XXXX
1=XXX.X
2=XX.XX
3=X.XXX
Press the
NET
key to save.
CAPACITY
Press the
NET
key to show the current capacity setting. Then press the
ON/ZERO
key to advance the flashing digit from 0 through 9 (
200.0
). Select the value then
press the
TARE
key to advance to the next digit location (
200.0
). Repeat the
process until the capacity has been entered. Press the
NET
key to save.
WEIGHING UNITS
Press the
NET
key to show the current setting. Then press the
ON/ZERO
key to
select the desired value: 1-2 where 1=Pounds Only and 2=Kilograms Only. Press
the
NET
key to save it.
(Please note, although selection 3 will display and can be selected, it is
INVALID
for the HSDC scale.)
CALIBRATION WEIGHT
Press the
NET
key to show the current calibration weight. Then press the
ON/
ZERO
key to advance the flashing digit of calibration weight from 0 through 9
(
150.0
). Select the value then press the
TARE
key to advance to the next digit
location (
150.0
). Repeat the process until the calibration weight has been
entered. Place this amount of calibration test weights on the scale, then press the
NET
key. The display will show
----
then:
Remove the test weights and press the
NET
key. The display will show
----
then proceed to the next prompt.
ZERO TRACKING RANGE
Press the
NET
key to show the current division setting. Values of
0
through
9
and
0.5
are valid for the zero tracking range. Press the
ON/ZERO
key to step through
and select
0.5
as the division value, then press the
NET
key to save. If a zero
tracking range division of
0
through 9 is desired, first press the
ON/ZERO
key to
select
0
, then press the
TARE
key to advance to the next digit location and press
the
ON/ZERO
key to select
0
through
9
divisions. Press the
NET
key to save.
4% ZERO TRACKING LIMIT
Press the
NET
key to show the current setting. Then press the
ON/ZERO
key to
toggle between yes and no.
YES=
4% limit,
no=
100% limit. Press the
NET
key to
save. (NOTE: 4% limit is for Canadian use)
POWER UP ZERO
Press the
NET
key to show the current setting. Then press the
ON/ZERO
key to
toggle between yes and no.
YES=
enable,
no=
disable. Press the
NET
key to save.
FILTERING
Press the
NET
key to show the current level of filtering. Then press the
ON/ZERO
key to select the desired value:
0=no filtering
1=minimal filtering
2=moderate filtering
3=custom filtering
Press the
NET
key to save setting.
If you select level 3 then:
Press
NET
to show current filter weight setting. Press
ON/ZERO
to select filter
weight level (1 through 99,-99 being the greatest filtering and 1 the least). Press
the
NET
key to save setting.
CAP=
dPP=
FLt=
Unt=
Lod=
UnLod
trA=
trL=
PUO=
F=