TMCM-6212 TMCL
™
Firmware Manual • Firmware Version V1.11 | Document Revision V1.07 • 2019-JAN-25
42 / 140
Bank 2 – States of the Digital Outputs
The states of the output lines (that have been set by SIO commands) can be read back using bank 2.
Digital Outputs in Bank 2
Port
Command
Range
OUT0
GIO 0, 2
0/1
OUT1
GIO 1, 2
0/1
OUT2
GIO 2, 2
0/1
OUT3
GIO 3, 2
0/1
State of the ENABLE Input
To query the state of the ENABLE input use GIO 10, 0. The return value will be 0 when enabled and 1 when
not enabled.