![Trinamic PD57-1060 Firmware Manual Download Page 99](http://html1.mh-extra.com/html/trinamic/pd57-1060/pd57-1060_firmware-manual_1163104099.webp)
PD57/60-1060 / TMCM-1060 TMCL™ Firmware Manual (V1.04 / 2011-AUG-29)
99
Copyright © 2011, TRINAMIC Motion Control GmbH & Co. KG
Number Axis Parameter Description
Range [Unit]
Acc.
212
maximum
encoder
deviation
When the actual position (parameter 1) and
the encoder position (parameter 209) differ
more than set here the motor will be
stopped. This function is switched off when
the maximum deviation is set to zero.
0… 65535
[encoder steps]
RWE
214
power down
delay
Standstill period before the current is changed
down to standby current. The standard value
is 200 (value equates 2000msec).
1… 65535
[10msec]
RWE
215
absolute encoder
value
Absolute value of the encoder.
0… 4095
[encoder steps]
R
254
step/dir
0 normal mode (move motor using
TMCL™ commands)
1 step/direction mode (move motor via
step/direction inputs)
0/1
RWE
Hardware related parameters for the more experienced users. Do not change unless you are
absolutely sure