PD57/60-1060 / TMCM-1060 TMCL™ Firmware Manual (V1.04 / 2011-AUG-29)
9
Copyright © 2011, TRINAMIC Motion Control GmbH & Co. KG
3.
Switch ON the power supply
The LED for power should flash now. This indicates that the on-board +5V supply is available.
If this does not occur, switch power OFF and check your connections as well as the power
supply.
4.
Start the TMCL-IDE software development environment
The TMCL-IDE is available on the TechLibCD and on
Installing the TMCL-IDE:
Make sure the COM port you intend to use is not blocked by another program.
Open TMCL-IDE by clicking
TMCL.exe
.
Choose
Setup
and
Options
and thereafter the
Connection tab
.
For RS485 choose
COM port
and
type
with the parameters shown below (baud rate 9600).
Click
OK
.
Attention:
Please refer to the TMCL-IDE User Manual for more information about connecting the
other interfaces (see
).
If you prefer to work with step/dir interface please proceed by using axis parameter
254 for switching to step/direction or back to TMCL™ (paragraph 5.7.5):
Command
Description
SAP 254, o, 0
Normal mode (move motor using TMCL™ commands)
SAP 254, o, 1
Step/direction mode (move motor via step/direction inputs)